Clearing Faults - EHEIM skimmarine100 Mode D'emploi

Nano écumeur
Masquer les pouces Voir aussi pour skimmarine100:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
English
Only use original EHEIM spare parts:
Lime wood airstone art. no. 7373328
8. Install the skimmer again in reverse order.
In order to prevent the wood pores of the airstone from swelling, put
the skimmer into operation immediately after the change.

7. Clearing faults

Attention! Electrocution!
▶ Before clearing faults, remove the mains plug of the pump.
Faults
Residual air at the
outlet
No air bubbles
No skimming
Extremely weak air
production
Large air bubbles
at the airstone
Defective skimming
Skimming too strong
(overflow)
For other faults, please contact EHEIM Service.
Possible cause
Can occur after the
water is changed
Skimmer is too low
Pump does not run
Lime wood airstone
swollen
The lime wood airstone
has reached the end of
its service life
The skimmer position is
incorrect
Skimmer is too low
Air volume too high
17
Remedy
▶ This ends automati-
cally after approx.
1 day
▶ Position the skim-
mer higher
▶ Check the pump
▶ Replace lime wood
airstone
▶ Replace lime wood
airstone
▶ Please note the
water level charac-
teristic line!
▶ Position the skim-
mer higher
▶ Reduce air volume

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

3551000

Table des Matières