Dometic ORIGO
➤ Place a class B-1 fire extinguisher in reaching distance.
6.3
Connecting the stove electrically
Warning – Danger of injury!
e
The stove may only be connected by a qualified specialist.
The following information is intended for technicians who are
familiar with the guidelines and safety precautions to be applied.
Observe the following safety instructions for the electrical connections:
Warning – Risk of short circuit!
e
Always use sockets which are grounded and secured by
residual current circuit breakers.
If you have to feed cables through metal walls or other walls with
sharp edges, use ducts or tubes to prevent damage.
Do not lay cables which are loose or bent next to electrically
conductive material (metal).
Fasten the cables securely.
Do not pull on the cables.
Lay the cables so that they cannot be tripped over or damaged.
➤ Check the type plate of the stove to ensure that the voltage of the unit
matches the voltage of the source.
➤ Install to a circuit breaker with at least 3 mm (
ing to chapter "Technical description" on page 9.
➤ Connect the three conductors of the connection cable via circuit breaker
to the AC mains:
– Black: L1, ungrounded conductor
– White: L2, neutral
– Green: ground
➤ Secure the cable with a clamp.
Mounting the stove