9. Specifications
9.4 Permissible temperature
Place, Situation
EN
Ambient
Medium
CIP and SIP
Autoclaving
Storage, transport
1) only for model PG43SA-S with option "autoclavable version"
9.5 Temperature effect
Model
PG43SA-S
PG43SA-C
9.6 Ingress protection per IEC/EN 60529
Model PG43SA-S: IP54
Model PG43SA-C: IP66
For further specifications see WIKA data sheets PM 04.15, PM 04.16
and the order documentation.
16
Permissible temperature
-20 ... +60 °C
≤ 150 °C
150 °C continuously for wetted parts
≤ 134 °C, 20 minutes
1)
-30 ... +70 °C
Deviation from the reference temperature
(+20 °C) at the measuring system
≤ ±0.5 %/10 K of full scale value
≤ ±0.8 %/10 K of full scale value
WIKA operating instructions pressure gauge, PG43SA-S, PG43SA-C