Configuration parameters per functional blocks
Equipment – Continue
Alarms
Alarm severity
The severity of each alarm is configurable individually with the following
attributes: major, major reverse, minor, minor reverse, none, none
reverse
Alarm Persistence
Persistence for the appearance: X = 0, 1, 3, 10 or 30s
Persistence for the disappearance: Y = 0, 1, 3, 10 or 30s
Loops
Remote loop indication, for loops 1 and 2, validated or not
(use of bits 1 to 4 of byte S1)
Central office mode (gathering remote indications) :
Yes or no
Routing
Static routes table
Putting ports into service: Ethernet, PPP1, PPP2, PPP3 or PPP4
Enabled / Disabled (port by port)
Port addressing (port by port) :
Ethernet
Interface IP address
Subnet mask
PPP Interface
Interface IP address
Subnetwork mask
Destination IP address (PPP interface only)
Management paths (port by port – PPP only) either:
MNGT
DCCr (A, B, C or D)
DCCm (A, B, C or D)
P#1, P#2
RIP routing validated or not (port by port)
Tableau 2-8– Configuration parameters (8/8)
No reproduction or communication without the written consent of SAGEM SA
Installation and User Guide - N56717020104
2 - OPERATION
Default
value
See tables
2-11 and 2-12
X = 3s
Y = 3s
Not validated
No
Not configured
Disabled
135.10.110.10
255.255.0.0
0.0.0.0
0.0.0.0
0.0.0.0
Not configured
Not validated
Page A2-9