EQUIPMENT
Optical specifications
Interface type
Bit rate
Standard
Encoding
Optical fiber
Guaranteed attenuation
Typical range
Connector
Mechanical specifications
Height
Width
Depth
Weight
Protection Class (IP)
Consumption
(see details below)
Environmental specifications
Mechanical
Climatic conditions
Operating temperature range
Extended operating temperature
range
Packaged transportation and
storage temperature
Relative humidity
EMC (Electromagnetic Compatibility)
And ESD
Safety
Energy
No reproduction or communication without the written consent of SAGEM SA
IC1.1 = L1.1 + S1.1 or IC1.2 = L1.2 + S1.2
or MM1 or S1.1 or L1.1
155.520 Mbit/s ± 20 ppm
ITU-T G.957/G.958
Not encoded (NRZ)
Single mode : 1310 nm (IC1.1, S1.1, L1.1) or 1550 nm
(IC1.2),
or multi-mode : 1310 nm (MM1)
UIT-T G.652.
IC1.1, IC1.2 : 0 – 28 dB with no external attenuator
L1.1 : 10 – 28 dB
S1.1 : 0 – 12 dB
IC1.1 : 0 – 60 km
IC1.2 : 0 – 90 km
L1.1 : 10 – 60 km
S1.1 : 0 – 15 km
MM1 : 0 – 2 km
IC1.1, IC1.2 : all ceramic FC/PC
L1.1, S1.1, MM1 : SC/PC
19" or ETSI
6 kg approx.
Corresponding to the IP of the rack used
< 40 W (to a equipped subrack of two cards
ADR Optical and two cards ADR LAN)
ETS 300 119-4 (19") or CEI 297-3 (ETSI)
ETS 300 019-2-3
CEI 721-1 (1993)
ETS300 019 part 1-3, class 3.1, 3.2
- 5 °C à + 45°C
- 25 °C to + 55°C (the MTBF [Mean Time Between
Failure] is significantly degraded)
- 40°C to + 70°C
EN 300386
NF EN 60950 and UTE C 92130
(the equipment does not provide the fire envelope)
ETS 300132-2
(is VLV equipment)
Installation and User Guide - N56717020104
4 - SPECIFICATIONS
4. SPECIFICATIONS
2U
300 mm
< 85%
Page A4-1