Fuse replacement:
Warnings: Disconnect the power cord before replacing a fuse and always
replace with the same type fuse.
With your hands, unscrew the fuse holder from its housing, remove the
damaged fuse from its holder and replace with exactly the same type of fuse.
Screw the fuse holder back in its place and reconnect power.
Exterior surface temperature under steady state conditions is 60℃.
General instructions
Before plugging this unit to power make sure the voltage in your area matches
the required voltage for the LED PAR-64 Pro. All PAR-LED PRO units can be
powered by 90/260V and 50/60Hz.
There are 2 ways to control your PROFESSIONAL LED PAR-64. The first
option is by „stand alone‟ function, and probably the most used option by an
external controller via DMX. The order in which fixtures are connected in a
DMX line does not influence the DMX addressing, the controller always will
recognize the fixture by its address.
XLR Wiring
Menu Control Panel
©Lotronic – 2011
XLR Pin Configuration
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive
DMX values and Functions:
CHANNEL
FUNCTION
1
RGB dimmer
2
Red dimmer
3
Green dimmer
4
Blue dimmer
5
Strobe
6
Function
7
Speed
Specifications
Operating modes: DMX512, Auto, Sound activated
Functions: Color changer (fast or slow), strobe & dimmer
Lamp: 36 x 1W hi bright LEDs
Life time of the lamps:80-100.000 operating hours
Colors:16.7 millions
Consumption: 36W
Power supply: 90V-250Vac/50-60Hz
IMPORTANT NOTE: Electric products must not be put into household
waste. Please bring them to a recycling centre. Ask your local
authorities or your dealer about the way to proceed
VOLUME
REMARK
0 – 255
RGB OFF – All ON
0 – 255
Red 0% - 100%
0 – 255
Green 0% - 100%
0 – 255
Blue 0% - 100%
0 – 255
Strobe from slow to fast
0 – 24
RGB dimmer
25 - 126
Auto
127 - 128
Red & blue
129 - 249
Sound activated
250 - 255
All ON
0 – 255
Speed from fast to slow
.
©Lotronic - 2011