salmson SILENT BOX Instructions De Montage page 17

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
ENGLISH
8 . OPERATING DEFAULTS
Before any repair, unplug the pump from electrical network.
After any repair check that the hydraulic trapdoor is well in position.
INCIDENT
8.1 THE PUMP TURNS BUT
a) The internal parts are clogged by
DOESN'T PROVIDE
foreign bodies :
WATER
b) Suction pipe clogged :
c) Air entry by the suction pipes :
d) The pump is empty :
e) The pressure at the suction is too
weak, it is often obvious when
there is also a cavitations noise :
f) The motor is supplied with a too
weak voltage :
g) The strainer foot valve is not
immerged :
8.2 THE PUMP VIBRATES
a) The pipes touch the box :
b) Foreign matters obstructing the
pump :
c) Difficult rotation of the pump :
8.3 THE MOTOR IS TOO
a) Too low voltage :
HOT
b) Foreign matters obstructing the
pump :
c) Ambient
+ 40°C :
d) The acoustic insulation clogs the
e) Altitude > 1000 m :
air circulation windows :
8.4 THE PUMP DOESN'T
a) No Amps :
TURN
b) Impeller blocked :
c) Thermal sensor opened :
d) Other failure :
8.5 THE PUMP DOESN'T
a) The pump doesn't turn at the nor-
GIVE ENOUGH PRES-
mal speed (foreign matter, supply
SURE
weak...) :
b) The motor is damaged :
c) The hydraulic part are worn :
d) Non return valve not opened :
e) Self priming valve not closed :
8.6 THE ELECTRIC PRO-
a) Voltage too weak :
TECTION SWITCH OFF
b) The phase is short cut :
c) The motor is damaged :
8.7 THE FLOW RATE IS
a) The suction (Ha) height is not
NOT REGULAR
observed :
b) The suction pipe has a diameter
smaller than the pump :
c) The strainer is clogged :
d) Air entry at the suction :
8.8 THE PUMP DOESN'T
a) The pressure Ha is above the
START IN AUTOMATIC
starting pressure adjust in factory :
MODE
b) The pressure sensor is damaged :
8.9 THE PUMP START
a) There is a leakage in the installation
WITHOUT ANY USE
(at the discharge) :
b) There is a non return valve at the
discharge. (The pump stops a brief time
and starts again during 1 minute) :
c) There is a leakage on the non return
valve of the pump (and on the
non return valve of the installation
is there is one) :
d) The priming valve is damaged :
CAUSE
a) Disassemble the pump and clean it.
b) Clean the suction pipe.
c) Check the tightness.
d) DRY RUN : restart the pump after refill it.
e) Too much loose of charge at the suction or suction head too high
(check the NPSH of installation).
f) Check the voltage at the plug.
g) Immerge the strainer (mini 70 cm). Weigth the pipe if necessary.
a) Re-locate the box .
b) Dismantle the pump and clean it.
c) Check the pump turns freely without abnormal sticking
(motor stopped).
a) Check the voltage at the plug.
b) Dismantle the pump and clean it.
Temperature
above
c) The pump is built for an maximum ambient Temperature of + 40°C.
d) Re-stuck the acoustic insulation in well position.
e) The pump is built for a nominal altitude 1000 m.
a) Check the electrical supply.
b) Clean the pump.
c) Let the motor cooled .
d) Check the failure table indicator.
a) Disassemble the pump and repair.
b) Replace it.
c) Change the impellers.
d) Check the opening or change.
e) Check the closing at low flow rate.
a) Check the good section of the leads of the electric cable.
b) Check the cable and replace if necessary.
c) Replace it.
a) Read carefully the installation manual.
b) The suction pipe must be with the same diameter than the pump.
c) Disassemble and clean.
d) Check the suction pipe. Check also the suction stage inside the pump.
a) The static pressure is above 1.5 bars. Adjust the potentiometer under the
start/stop button (See Chapter 7).
b) Check that the pump start correctly in continuous mode. Replace the
complete control panel.
a) Check the installation (toilets, tap...). Or install a tank.
b) Cancel the non return valve. It is not compatible with the non return valve
of the pump.
c) Replace the non return valve stage inside the pump and the O ring. If the
non return valve is worn by the sand you may use a strainer foot valve with
adapted filter.
d) Replace it.
REMEDIAL ACTION
17

Publicité

Table des Matières
loading

Table des Matières