TROUBLE SHOOTING
Problem
The unit runs but no suction
or poor suction.
The unit runs but no suction.
The unit runs but poor
suction.
Machine blows dust.
Abnormal sound from
machine.
2011-06-09
Service performed by other than Dustcontrol or its aut-
horized agent voids automatically the warranty. No other
warranty express or implied is applicable.
Fault
The compressed air is not
connected or poor net
Hose not connected.
Hose plugged.
No plastic sack on the
cyclone.
Hole in the hose.
Plugged fi lter.
Hose too long or too small.
Hose is kinked.
Machine top is mounted
incorrectly.
Dust is packed in the
cyclone.
Filter is perforated or has
come loose.
DC 3800 TR S - 11
Solution
Check the pressure of the
compressed air at the pressure.
machine when running.
The pressure should be
at least 6 bar.
Connect the hose.
Find and remove block.
Mount the correct sack.
Change or repair hose.
Clean or change fi lter.
Change the hose.
Check and free.
Adjust the mounting.
Take off the top and clean
out.
Check the fi lters and change
if necessary.
Order service.