Polar Refrigeration CK640 Mode D'emploi page 13

Masquer les pouces Voir aussi pour CK640:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
Internal Diagnostics
Code
Message
Remedies
Pr1
Cabinet
probe error
Pr2
Pin probe
error
CK640_ML_A5_v3_20190925.indb 13
Consequences
See P0
Consequences if the error occurs while in "stand-by" mode:
parameter
If parameter C11 is set to 0, it will not be possible to start
Check probe
any of the cycles
integrity
If parameter C11 is set to 1, the pin probe will function as
Check probe-
the cabinet probe and only timed cycles will be allowed to
device
start
connection
Consequences if the error occurs during a timed chilling
Check the
operation:
cabinet
If parameter C11 is set to 0, the cycle will be interrupted
temperature
If parameter C11 is set to 1, the pin probe will function as
the cabinet probe and the chilling operation will continue
Consequences if the error occurs during a set-temperature
chilling operation:
If parameter C11 is set to 0, the cycle will be interrupted
If parameter C11 is set to 1, the pin probe will function
as both the cabinet probe and pin probe and the chilling
operation will continue
Consequences if the error occurs during a storage operation:
Parameter C11 is set to 0, the compressor activity will
depend on parameters C4, C5 and C6
If parameter C11 is set to 1, the pin probe will function as
the cabinet probe and the storage operation will continue
The same
Consequences if the error occurs while in "stand-by" mode:
as for the
Only timed operation cycles will be allowed to start
previous case,
Consequences if the error occurs during a timed chilling
but in relation
operation:
to the pin
Chilling will continue
probe
Consequences if the error occurs during a set-temperature
chilling operation:
Chilling will continue in timed mode
Consequences if the error occurs during storage mode:
Storage will continue
UK
13
2019/9/25 13:40

Publicité

Table des Matières
loading

Table des Matières