Test To Check Correct Pin Probe Insertion
•
Set-temperature cycles are preceded by a test step in order to check correct
pin probe insertion.
•
If power is interrupted during the test, when power is restored, the test will
start again from the beginning.
The test has two stages:
•
if the outcome of the first stage is positive, the second will not be run
•
if the outcome of the first stage is negative, the second will be run.
•
The outcome of the first stage is positive if "the temperature measured by the pin probe - the
temperature of the cabinet" is greater than the value set by parameter rc at least 3 times out of 5 (the
comparison is made every 10 s); if parameter rc is set to 0, neither the first nor second stages will be
run.
•
The outcome of the second stage is positive if the difference "temperature measured by the pin probe
- temperature of the cabinet" is greater by at least 1ºC/1ºF (with respect to the previous comparison)
at least 6 times out of 8 (the comparison is made every "rd/8 s")
If the outcome of the test is positive:
•
the cycle will be activated
•
the cycle will be started in timed mode
•
the LED
will flash
Setting The Configuration Parameters
The parameters are arranged on two levels.
To access the first
•
level:
•
To access the
•
second level:
•
•
•
•
•
CK640_ML_A5_v3_20190925.indb 11
the display shows the cabinet temperature
if chilling had a positive outcome, the LEDs
chilling had a negative outcome, the LEDs
LED
will flash.
the parameter rA sets the operational set point
press
several times to:
- display the message "nEg"
- exit the procedure, or leave for 15 seconds
press
for 2 seconds
ensure the device is in "stand-by" mode and no procedures are running
press
and
for 4 s: the display will show "PA"
access the first level
press
or
to select "PA"
press
press
or
within 15 s to set "-19"
press
or leave for 15 s
press
and
for 4 s: the display will show "CA1"