night function, i. e. if the illuminance falls below 2 lux, it
will switch to black-and-white reproduction.
As the camera is weatherproof (class of protection
IP 68), it is also suitable for outdoor use. The power sup-
ply unit, however, must always be operated indoors.
4 Mounting
1) For removing the sunshield, release the middle
screw (2) on the sunshield. Thus, the sunshield can
be displaced in the guide rail (3) on the upper side
of the camera so that it can be pulled off to the rear
(see fig. 1).
2) Screw the supplied bracket [or another bracket with
1
6.3 mm (
/
") thread] to one of the three thread
4
jacks (1):
for wall mounting to the lower thread jack of the
camera housing (fig. 3)
for ceiling suspension to the thread jack of the sun-
shield or – with the sunshield removed – to the
upper thread jack of the camera housing.
3) Mount the bracket to the wall or ceiling by means of
the dowels and screws supplied.
5 Operation
1) For power supply, the camera requires a constant
current of 450 mA (also see label "Constant Current
450 mA" on the camera and the power supply unit).
When manufacturing the unit, this current has been
adjusted with the switches (10) on the power supply
unit. Prior to setting into operation check if the
switches are still in the correct position:
An incorrect adjustment may cause damage.
2) Connect the cable (4) of the camera to the jack TO
CAMERA (12) of the power supply unit. The length
of the cable is 30 m. In case of a high-quality cable,
the maximum length may be 500 m:
Cable type
RG-58U
RG-59U
RG-6U
The following cables from MONACOR are suitable
up to 350 m: VCC-59, VCC-59 / SW, VCC-259 / SW.
3) Connect the video output VIDEO OUT TO MONI-
TOR (11) of the power supply unit via a 75 Ω coax-
All rights reserved by MONACOR
be reproduced in any form or by any means for any commercial use.
max. cable length
200 m
350 m
500 m
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may
ial cable to the video input jack of the monitor or of
a camera switcher or video splitter. Observe the
correct 75 Ω termination.
4) Connect the plug of the mains cable (8) to a mains
socket (230 V~ / 50 Hz) and switch on the power
supply unit with the POWER switch (7). The power
LED (6) will light up.
CAUTION In case of darkness (illuminance below
10 lux) the IR LEDs switch on. When setting up
the camera, never look directly into the lit IR LEDs
from a close range. The infrared light may cause
eye irritation. However, the infrared radiation is far
below the emission limit and rated risk-free
according to EN 62471.
5) Also switch on the monitor connected. Release the
locking screw (5) of the camera bracket, adjust the
camera to the surveillance zone, then retighten the
screw.
6 Specifications
Image sensor: . . . . . . . . . . . 8.5 mm (
Number of pixels: . . . . . . . . hor. 1020 × vert. 596
Resolution: . . . . . . . . . . . . . 680 lines
Synchronization: . . . . . . . . . CCIR, hor. 15 625 Hz,
Video system: . . . . . . . . . . . PAL
Lens: . . . . . . . . . . . . . . . . . . 1 : 2.0 / 6 mm
Minimum illumination (IR off): 0.01 lux
Range of the IR illumination: 50 m
Autom. electronic shutter: . .
Other functions: . . . . . . . . . AGC, backlight compen-
S / N ratio: . . . . . . . . . . . . . . > 52 dB
Video output: . . . . . . . . . . . 1 Vpp / 75 Ω
Protection class of housing: IP 68
Admissible
ambient temperature range: -10 °C to +50 °C
Power supply: . . . . . . . . . . . 230 V~ / 50 Hz / 10 VA
Dimensions, weight
Camera: . . . . . . . . . . . . . . ∅ 60 mm × 110 mm,
Power supply unit: . . . . . . 218 × 106 × 44 mm,
Subject to technical modification.
1
/
") CCD chip
3
vertical 50 Hz
1
1
/
–
/
s
50
100 000
sation, automatic white
balance
0.5 kg
1.2 kg
GB