Installation Instructions

ASSEMBLY AND INSTALLATION

WARNING:
Failure to provide adequate structural strength
for this component can result in serious personal injury or
damage to equipment! It is the installer's responsibility to
make sure the structure to which this component is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.
1.
Place two U-bolts (B) over 1" (minimum) steel supporting
truss or pipe. (See Figure 1)
Supporting
pipe
Figure 1
2.
Raise truss plate (A) up and insert U-bolts through holes in
truss plate. (See Figure 2)
NOTE:
If installing truss plate (A) to pipe, ensure that pipe fits
into notches in plate. (See Figure 2)
Pipe should fit
into notches
(A)
3
(F) x 4
4
Figure 2
(B) x 2
(B)
2
(G) x 4
3.
Loosely install 3/8" nuts (F) and 3/8" washers (G).
4.
Level mount and tighten nuts (E). (See Figure 2)
Installing Extension Column
WARNING:
Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer's responsibility to make sure the combined weight of
all components located within the mounting system of the
CPA365 does not exceed 500 lbs (226.8 kg).
1.
Route cables through extension column (not included).
2.
Install UL Listed CPA Extension Column Series (not
included) into CPA365.
NOTE:
Installation of hex head self-tapping screws will be
easier when screws are carefully aligned with holes in
extension column, and a drill and nut driver is used. If
a drill will NOT be used, a small amount of pressure will
be needed to get the self-tapping screws started.
3.
Secure extension column to CPA365 using four 5/16-18 x 1"
hex head self-tapping screws (D), four 5/16" split lock
washers (E) and four 5/16" flat washers (H) through holes in
extension column. (See Figure 3)
4.
Install one 5/16" x 1/2" set screw (C) into threaded hole,
tightening firmly against column. (See Figure 3)
(E) x 4
(H) x 4
2
(C) x 1
4
Extension
column
(not included)
Figure 3
5.
Complete installation following appropriate mount
installation instructions.
CPA365