Possible faults
Before each maintenance and cleaning work
switch off device
wait for stop of chain saw
pull out main plug
After each fault clearance, put into operation and recheck all security installations.
Fault
Chain saw does not
initiate after switching on
Chain saw works with
interruptions
Chain saw picks, vibrates
or does not saw correctly
Chain saw does not work
with full power
Saw chain gets hot
no saw chain lubrication
Technical data
Typ
Year of construction
Motor rating P
1
Mains voltage / Mains frequency
No-load speed n
0
Chain wheel (number of teeth/pitch)
max. guide bar length (length of sword)
Saw chain speed
Oil tank volume max.
Protection class
Sound power level L
**
PA
measured sound power level L
guaranteed sound power level L
Uncertainty K
/ K
PA
WA
Hand-Arm-Vibration
Uncertainty K
hd
Weight
Saw chain type
Pitch / drive link thickness
* (according to EN ISO 3744)
** (according to directive 2000/14/EC)
Possible cause
Chain brake
no power
Extension cable damaged
Main plug, motor or switch defect
external loose connection
internal loose connection
Circuit closer/breaker defect
Chain edgeless
Chain worn
Chain tension
Chain not assembled correctly (teeth face to
wrong direction)
Extension cable too long or diameter too small
Power outlet to far away from main connection
no oil in the tank
oil flow canal blocked
chain tension too high
Chain edgeless
no oil in the tank
oil flow canal blocked
*
WA
**
WA
Removal
Release chain brake
Check power supply, power outlet, fuse
protection
Check extension cable, exchange defect cable
immediately
Have motor or switch checked by an approved
electrician or replaced by original spare parts.
Check power supply, power outlet, fuse
protection
Check extension cable, exchange defect cable
immediately
Please contact the after sales service.
Please contact the after sales service.
Chain must be regrinded or exchanged
Exchange chain
Check and adjust chain tension
Assemble chain again
Use extension cable with sufficient diameter
Use power outlet which is nearer within the
working area
Refill oil
Clean oil flow canal
Adjust chain tension
Chain must be regrinded or exchanged
Refill oil
Clean oil flow canal
9.525 mm (3/8") / 1.3 mm (.050")
KS 2002/40
see last page
2000 W
230 V~ / 50 Hz
8463 min
–1
7 x 9.525 mm (3/8")
400 mm
13.5 m/s
200 ml
92.55 dB (A)
103.55 dB (A)
109 dB (A)
2.5 dB (A)
a
= 4.886 m/s²
hd
1.5 m/s²
ca. 5.7 kg
91 PJ 057X (Oregon)