Maintenance; Maintenance Program; Spare Parts - Bosch ACS 753 Notice Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 76
en
66 | ACS 753 | Maintenance
7.

Maintenance

!
Do not use abrasive detergents, solvents (petrol,
diesel, etc.) and rough workshop rags to clean the
station. Clean only with a soft cloth and a neutral
detergent.
i
In case of refrigerant leaks during normal use of the
machine and during installation, maintenance or
repair of the machine, no refund will be made by the
manufacturer.
CAUTION: disconnect the power supply
before any maintenance operation.
7.1

Maintenance program

WARNING: to prevent accidents, only
qualified personnel must perform
inspections and repairs on the station. Read
and follow the instructions and warnings in
this manual. Wear protective clothing that
include safety glasses and gloves.
Maintenance operation
Recommended interval
Filter replacement
The filter must be replaced after
68 kg (150 lb) of refrigerant
has been filtered. See Filter
Maintenance in the Maintenance
section of this manual.
Vacuum pump oil change When the filter is replaced or every
100 hours. See vacuum pump oil
change in the Maintenance section
of this manual.
Checking the correct
Every month.
operation of wheels and
rollers
Checking the internal
Every month. See Checking the
scale calibration
calibration in the Maintenance
section of this manual. Every year,
all scales must be calibrated by an
authorized Bosch service center.
Setting to zero of PAG
Whenever necessary. See Scale
and POE oil injection, oil
Reset in the Maintenance section of
drain and UV dye scales
this manual.
Leak check
Every year - performed by an
authorized Bosch service center.
Cleaning the air suction
Every month. Use a clean cloth.
panels
Cleaning the panel and
Every month. Use a clean cloth.
control panel
Inspection of the
Everyday.
integrity of the power
cable and hoses
Lubrication of wheel
Every month.
bearings and inspection
of brake components
Inspection of solenoid
Every year - performed by an
valves
authorized Bosch service center.
|
SP00D00596
2019-07-04
7.2

Spare parts

CAUTION: to prevent accidents, for repairs
use only the components included in
the spare parts list as these have been
carefully tested and selected by Bosch.
Replacement component
Calibration weight
Filter
Oil drain bottle
PAG oil injection bottle
POE oil injection bottle
UV dye bottle
Printer paper (5 rolls)
Low pressure service connection
High pressure service connection
Service hose (low pressure, blue)
Service hose (high pressure, red)
Quick Coupler for Commercial Tank
1/4" SAE
Tank Adapter W21.8-14 x 1/4" FL
Vacuum pump oil (600 ml)
Code
SP01100095
SP01100355
SP00101727
SP00101414
SP00101412
SP00101418
SP00100087
SP00100082
SP00100083
SP00101648
SP00101649
SP00100019
SP00100080
SP00100086
Robert Bosch GmbH

Publicité

Table des Matières
loading

Table des Matières