Connection
These hobs are delivered with type H 05 VVF power cable (1.5mm²) with 3/5 conductors (including a
green/yellow earth wire), which must be connected to the power supply via a plug that complies with
publication CEI 60083 or an all-pole cut-out unit with contacts that open by at least 3mm.
If the cable is damaged, it must be replaced by the manufacturers, their After Sales Service or another
similarly qualified person for avoiding any possible risk of accident.
When connected to 400 V2N three-phase, if you hob malfunctions, check that the neutral cable is pro-
perly connected.
"When installing the cooktop, precautions must be taken to avoid damaging the power cable with the
sharp edges".
- 220-240 V monophase
fuse 32 Amp
Green/yellow
Blue
brown
Black
L
N
Blue
brown
L
N
- 220-240 V monophase
fuse 16 Amp
Installing your hob in complete safety
brown
Blue
Green/yellow
5
- 400 V 2N three-phase
fuse : 16 Amp
Separate the 2
phase wires L1
and L2 before
connecting
N L1
L2
220 -240V∼ ∼ 50-60 Hz
Total energy consumption
TV300.......3 kW
TV310.....6,5 kW
TV311.....6,9 kW
Green/yellow
Black