Operating principle
Blocking protection
Operating button
5 sec.
12
Valves
The pump is equipped with a non-return valve (1)
on the pressure side and with a ball shut-off
valve (2) on the suction side.
When replacing the motor head (3), it is sufficient
to de-energise it by unplugging the connector (5)
and to close the ball shut-off valve at the rotating
slot (4). The motor head can then be simply
unscrewed.
If the pump is switched off by the time-switching
function, the pump switches on automatically
for 10 seconds once every 60 minutes. This auto-
matic function cannot be switched on/off.
4.3
The menu
All of the settings in the menu are made using the
operating button:
•
Press > 5 seconds
to call-up the menu.
•
Press briefly
to select menu items and confirm
entered parameters.
•
Turning
to select menu items and adjust
parameters.
Symbols
The following symbols are shown in the menu:
•
Clock menu
Setting the current time.
•
Time switching function menu
Setting the parameters:
Page 15.
5 sec.
WILO SE 05/2021