BTL7-S5 _ _ ( _ )-M _ _ _ _ -BE/BF/CE/ZE/ZF-S32/S115/KA _ _ /FA _ _
Magnetostrictive Linear Position Sensor — Rod Style
7
Configuration with the BTL7 Configuration Tool (only for BTL7-S510(B)-...)
7.1
BTL7 Configuration Tool
The BTL can be quickly and easily configured on the PC
using the PC software BTL7 Configuration Tool.
The most important features include:
–
Online display of the current position of the magnet
–
Graphic support for setting the functions and
characteristics
–
Display of information on the connected BTL
–
Selection of displayed number formats and units
–
Possible to reset to the factory settings
–
Demo mode without a connected BTL
The PC software and associated manual can
be found in the Internet under
www.balluff.com.
7.2
Connecting the USB communication box
For a BTL with connector the communication box must be
inserted between the BTL and the controller. The
communication box is connected to the PC via a USB
cable.
USB cable
Connection cable approx. 0.3 m
with connector (socket)
8-pin
Fig. 7-1:
Connecting the communication box with connector
For a BTL with cable connection the communication lines
La, Lb and GND are connected to the USB communication
box.
USB cable
Fig. 7-2:
Connecting the communication box with a cable connection
When reading or writing data using the BTL7
Configuration Tool, the LED 2 flashes green.
www.balluff.com
Connection cable
approx. 0.3 m with
connector (plug)
Controller
6-pin
Controller
8-pin
Connection cable
approx. 0.6 m with
luster terminal
7.3
Configuration options
Prerequisites
–
USB communication box connected to the BTL and
PC.
–
Software correctly installed.
–
BTL connected to the power supply.
–
Magnet on BTL.
Output functions
Position: Position in the measuring range.
–
Speed: Speed of the magnet; the sign indicates the
–
direction of movement. A movement from the starting
point to end point is output with a positive sign; a
movement from the end point to the starting point is
output with a negative sign.
–
Speed (unsigned): Speed of the magnet, the direction
of movement cannot be read.
–
Differential position: Distance between two magnets.
Selection is only possible if two magnets have been
selected.
–
Speed difference: The speeds of two magnets are
subtracted to form a sum. Selection is only possible if
two magnets have been selected.
Freely configurable characteristic curve
–
The gradient of the characteristic curve can be set by
adjusting the resolution.
–
The limits can be adjusted to the measuring range.
–
The error value can be set.
Boundary conditions for several magnets
–
Two magnets can only be selected from a nominal
length ≥ 90 mm.
–
The distance between two magnets must be ≥ 65 mm.
DANGER
Uncontrolled system movement
When starting up, if the position measuring system is
part of a closed loop system whose parameters have not
yet been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
► The system must be taken out of operation before
configuration.
► The BTLs may only be connected to the
communication box for configuration.
► The communication box must be removed after
configuration.
english