BTL7-A/E501-M_ _ _ _-A/B/Y/Z(8)-S32/S115/S140/KA_ _/FA_ _
Micropulse Transducer - Rod Style
6
Configuration with the Micropulse Configuration Tool
6.1
Micropulse Configuration Tool
NOTICE!
Interference in function
Configuration with the Micropulse Configuration Tool
while the system is running may result in malfunctions.
► Stop the system before configuration.
The BTL7-A/E... USB-Configurable transducer can be
configured quickly and simply on a PC using the
Micropulse Configuration Tool PC software.
The most important features include:
–
Online display of the current position of the magnet
–
Graphical support for setting the functions and curves
–
Display of information on the connected transducer
–
Selectable number formats and units for display
–
Resetting to factory settings is possible
–
Demo mode without having transducer connected
The PC software and associated manual can
be found in the Internet under www.balluff.com/
downloads-btl7.
6.2
Connecting the USB communication box
With BTL7-A/E... transducers with connectors, the
communication box must be looped in between the
transducer and controller. The communication box is
connected to the PC via a USB cable.
USB cable
Connection cable approx. 0.3 m with
connector (socket)
Fig. 6-1:
Connecting the communication box with a connector
14
english
Connection cable
approx. 0.3 m with
connector (plug)
Controller
8-pin
6-pin
With a BTL7-A/E...-Cable transducer, the communication
lines La, Lb and GND must be connected to the USB
communication box.
USB cable
Fig. 6-2:
Connecting the communication box with a cable connec-
tion
When reading or writing data via the
Configuration Tool, both LEDs flash green.
6.3
Configuration options
Prerequisites
–
USB communication box connected to the transducer
and PC.
–
Software correctly installed.
–
Transducer connected to the power supply.
–
Magnet on transducer.
Magnets and outputs
–
One or two magnets can be selected (factory setting:
one magnet)
–
Two outputs can be assigned independently
Output functions
–
Position: position in the measuring range.
–
Velocity: velocity of the magnet. The sign indicates the
direction of movement. Movement from the null point
to the end point is output with a positive sign.
Movement from the end point to the null point is output
with a negative sign. Max. detectable velocity range of
−10 to +10 m/s.
–
Velocity (no sign): velocity of the magnet. The
direction of movement cannot be read. Max.
detectable velocity range of 0 to 10 m/s.
–
Differential position: Distance between two magnets.
Selection is only possible if two magnets have been
selected.
Controller
8-pin
Connection cable
approx. 0.6 m with
luster terminal