English
Dimensions [mm]
H
W
T
US 62 380
190
210
US 73 380
195
210
US 75 395
200
230
US 102 410
190
210
US 103 410
195
210
US 105 425
200
230
US 151 360
220
310
US 152 435
190
210
US 153 435
190
210
US 155 450
200
230
US 251 360
220
310
US 253 400
190
280
Pumps with special float assembly, mat. no.
17424
H
US 62, US 73
380
US 75
395
US 102, US 103
410
US 105
425
US 152, US 153
435
US 155
450
Switching points On - Off for an attached con-
trol
●
○
US 62, US 73
240
125
US 75
255 140
US 102, US 103
270
155
US 105
285
170
US 152, US 153
295 180
US 155
310
195 225
4 4
Electrical connection
The relevant standards (such as EN standards),
country-specific regulations (such as VDE in
Germany), and the regulations of the local
power supply companies must be observed.
Attention ! Never put the mains plug or a free
lead end in water! If water gets into the plug,
this can cause malfunctions and damage.
The pump is provided with a winding thermo-
stat. In case of unacceptably high temperatures
it switches off the pump to protect it against
BS
TS
possible damage. Unacceptably high tempera-
225
325
tures may result e.g. from dry running or me-
230
325
chanical or electrical overload.
240
335
225
325
230
325
nect the device from the mains before remedy-
240
335
ing the fault! In order to do this, unplug the
pump from the mains supply or remove the
pre-fuses of the pump controls!
225
325
225
325
US 62 to US 105
240
335
Observe the operating voltage (see the type
plate)! Only connect the pump to sockets that
have been installed properly in accordance
with the regulations and are fitted with a 16 A
(delay) fuse.
Pumps without built-in level control can also
be operated automatically through the use of
our level controls. Our ready to connect level
BS
TS
controls can be installed without specific elec-
255
280
trotechnical skills.
205
290
255
280
US 151 to US 253
265
290
Observe the operating voltage (see the type
255
280
plate)! Only connect the pump to sockets that
have been installed properly in accordance
205
290
with the regulations and are fitted with a 16 A
(delay) fuse.
The pump must only be operated with the
standard motor protection plug. Models with-
out motor protection plug must only be oper-
●
○
ated using the level controls with integrated
motor protection that are approved by JUNG
155
105
PUMPEN. These pumps must be connected by
170
120
a qualified electrician.
185
135
The overload protection (only for D and DS)
must be set to the nominal current of the pump
200 150
(see type plate) + 10%. If the motor protection
210
160
plug or the level control require to be opened
in order to reset or set the overload protection,
175
this must only be done by a qualified electri-
cian!
Only qualified electricians may carry
out electrical works to the pump or
the controls.
The pump is switched on again auto-
matically after cooling down - risk of
injury! For this reason, always discon-
Disconnect the device or the pump
from the power supply before open-
ing!
If there is a blockage in the pump, the overload
protection may be triggered. After rectifying
the fault the "reset" button on the motor pro-
tection plug must be pressed to switch the
pump on again. Pumps which are operated
with a separate level control have the overload
protection in the level control.
Rotational direction
The rotational direction must be checked be-
fore installation! If the rotational direction is
correct, the start-up jolt should be in the oppo-
site direction to the rotational direction arrow
on the motor housing. The wrong rotational
direction is also indicated if the pump performs
inadequately when installed, or if loud noises
can be heard during operation. If the rotational
direction is wrong, 2 phases of the supply cable
must be swapped over.
The start-up jolt can be very forceful.
Installation
The pump must be installed as shown in the
examples. For installations in accordance with
DIN EN 12056-4, the pressure pipe must be laid
in a loop above the local backflow level and
protected with a backflow prevention valve.
A correspondingly larger diameter pipe should
be used for longer pressure pipelines to avoid
pipe friction losses.
In contrast to pumps with built-in level control,
the ON and OFF switching heights of pumps
without built-in level control are variable by the
use of a separate level control.
Permanent venting of the ring housing may be
necessary if the pump runs dry from time to
time (pressure outlet surfaced). This can occur
for example if the residual water in the collect-
ing chamber evaporates or if the pump runs in
"snore" mode during the test run.
To vent the pump housing on pumps US 151,
US 251 and US 253 the pressure pipe must be
drilled above the pressure outlet to provide a 6
mm drill-hole. On all other pumps, the M8 hex-
agon socket screw under the (brass) oil screw
must be removed.
Attention!If the pump is malfunctioning, part
of the contents of the oil reservoir could escape
into the pumping medium.
Dimensions of sump
Single installation with pump base: 40 x 50 cm
Single installation with guide rail system: 40 x
70 cm
Duplex installation: 70 x 70 cm