ENGLISH
1) INSTALLATION INSTRUCTIONS
2) PRECAUTIONS FOR USE (The product guarantee depends on the respect for these rules)
INSTALLATION and START UP
For products delivered with filters, these must be installed in accordance with the instructions.
Before commissioning any of our valves, it is essential to carefully bleed the pipes that can damage the mechanisms or water passages
(PRESTO® heads that can be dismantled from front).
Recommended operating pressure according to NF EN 816: 1 to 5 bars.
CLEANING
The chrome-plated coating of PRESTO® valves must be cleaned only with soapy water.
Abrasive, acid, alkaline or ammonia-based household products are prohibited.
MAINTENANCE
Never lubricate the internal mechanism, particularly the caps and valve seals.
3) From 20 minimum to 80 maximum
4) HOT
5) COLD
6) 7 pozidriv screws Ø4.5 mm pins supplied
7) Shut-off valve + bushing to be installed on the Hot Water side (delivered in a pouch)
8) from the floor
9) Wall attachment plate
10) TOP INLET VERSION
27808 DL800S with soap holder
11) BUILT-IN INLET VERSION
27820 DL800S with soap holder
12) INSTALLATION OF TOP INLET VERSION
13) INSTALLATION OF BUILT-IN INLET VERSION
14) Shut-off valve + bushing to be installed on the hot water side (delivered in a pouch)
15) OPERATION OF THE CONTROLS
16) Pressing this causes the flow to stop
17) Pressing on the lower part triggers the flow.
18) Commissioning
Drain the pipe
Connect and open the shut-off valves.
Press several times on the controls to force the air out
Adjust the angle of the jet
Flow
Delivered with a flow limiter 10 l/min
19) ADJUSTMENT AND MAINTENANCE OF THE THERMOSTATIC CARTRIDGE
20) The Mixing valve allows the user to select the temperature of the lukewarm water, between the cold water temperature and the
lukewarm water temperature preset at 38° C.
21) MODIFICATION OF THE MAX OPERATING TEMPERATURE
22) On delivery black line or point Ø1.5 vertically aligned
23) Red Ring
24 24 24 24) ) ) ) • Rotate the centre spindle according to the desired temperature: 1 notch = 2° C
• Raise the lever keeping the mark (A) vertical
25 25 25 25) ) ) ) IT IS NOT RECOMMENDED AND DANGEROUS TO DELIVER HOT DOMESTIC SUPPLY WATER AT MORE THAN 42° C
INSTANTANEOUS SHUT-OFF OF THE HOT WATER SUPPLY IN CASE OF ACCIDENTAL RUPTURE OF THE COLD WATER SUPPLY.
26) MAINTENANCE OF THE THERMOSTATIC COMBINATION CARTRIDGE
Clean or replace
Disassembly:
Close the water inlets
Remove the lever (See below)
Remove, clean and reinstall as indicated.
27) Black line or point Ø 1.5 vertically aligned
28) Index on top
29) Stop 38° c
30) Vertical Flats
31 31 31 31) ) ) ) • Reinstall the lever by keeping the mark (A) vertical
32) MAINTENANCE OF THE SHOWER
Part no. : 90207 20 safety wires
Part no. : 90186 20 O-rings
Part no. : 90184 1 grille + 1 picot membrane + 1 flow regulator 10l/min
Part no. : 90185 1 grille + 1 picot membrane
Part no. : 90183 Shower priming pump + 2 screws
Part no. : 90719 Shower priming pump + 2 screws
Part no. : 90145 Flow regulator 6 l/min
Part no. : 90178 Flow regulator 8 l/min
Part no. : 90146 Flow regulator 10 l/min
Part no. : 90885 Hand-held shower
Part no. : 90886 Flexible hose
Part no. : 90887 Thermostatic cartridge
33) MAINTENANCE OF THE PRIMING PUMP AND STOP BUTTON
34) Close the water inlets
Remove the front face of the panel
35) CONTROL CIRCUIT WIRING LAYOUT
36) RASSEMBLE WHILE RESPECTING THE REVERSE PROCEDURE
37) This document is not contractual; we reserve the right to modify the characteristics of our products without notice.
38) PATENTED and REGISTERED MODELS

Publicité