Calculating length of elbow vent pipevacuation *:
•
30 Pa = 1 ml duct
30 Pa = 1 90 ° elbow
The length of vent pipe between the hood (sensor) and the separate motor determines the average pressure
•
in pascal (Pa) that the separate motor is provided, and inverse.
eg to 3 m hose and 2 90 ° elbows vent pipe between the hood and
separate motor requires a mean pressure of 150 Pa
The separate motor F PRO ENERGY EU 2016 requires a power of 220-
The power supply is done via the separate motor (motor powers the hood
into electrical energy by the connecting cable supplied with the 9-way (6).
The separate motor is fitted with a 3 x 0.75 mm² HO5VVF power cord including a standardised 10/16 A plug with an
earthing system.
Type of protection: category 1
Power supply voltage: 220-240V mono - 50/60Hz.
Check that the voltage of the supply circuit is identical to the values indicated on the descriptive plate inside the hood.
If the hood is directly connected to the network (without its plug), an omnipolar switch with a 3mm contact point-gap should
be installed just before the hood. The earth wire (yellow and green wire) should not be interrupted by this switch.
TECHNICAL FORM
ELECTRICAL
240V
Provide a power socket near the engine .
* General information for a specific data: please contact our customer service.
GB