Remove the cover plate
To perform maintenance work it is necessary to remove the cover plate.
14.1 Remove the screws (a) from the bottom of the cover plate.
14.2 Remove the cover plate (b).
14.3 Close the flow volume regulators (see
14.4 Trigger the valve.
15. Replacing the Plastic Hose
15.1 Remove the cover plate (see
15.2 Press the ring in the arrow direction.
15.3 Pull out the plastic hose.
15.4 Apply a slight pressure to push the plastic hose inwards to the stop.
15.5 Open the water volume regulators (see
15.6 Mount the cover plate.
16. Fault Correction
Fault
Water does not flow
Water flows conti-
nuously
Water flow too weak
Water flow too strong
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our service department!!
8
Instruction Step
Chapter
14.).
Cause
– Water supply interrupted
– Water flow regulator closed
– Solenoid valve faulty
– Electronic module defective
– Solenoid valve dirty
– Solenoid valve faulty
– Water volume regulator not fully
opened
– Supply pressure too low
– Flush volume adjustment is
incorrect
– Flush volume adjustment is
incorrect
10.2).
Instruction Step
10.2).
Remedy
➯ Restore it
➯ Open it
➯ Replace it
➯ Replace it
➯ Clean it
➯ Replace it
➯ Open it
➯ Check it
➯ Adjust it