Preparation For Use - DeWalt D55153 Guide D'utilisation

Masquer les pouces Voir aussi pour D55153:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The air compressor pump and shroud are designed to allow for proper
cooling. The ventilation openings on the compressor are necessary
to maintain proper operating temperature. Do not place rags or other
containers on or near these openings.
Place the air compressor on a flat surface resting on the rubber feet.
NOISE CONSIDERATIONS
Consult local officials for information regarding acceptable noise
levels in your area. To reduce excessive noise, use vibration mounts
or silencers, relocate the unit or construct total enclosures or baffle
walls. Contact a D
WALT service center or call 1-800-4-D
e
for assistance.
ELECTRICAL
Refer to all safety instructions before using unit. Observe extension cord
safety instructions if necessary. Always move the On/Off switch (A) to
the OFF position before removing the plug from the outlet.
TRANSPORTING
When transporting the compressor in a vehicle, trailer, etc., ensure
that the tank is drained and the unit is secured. Use care when driving
to avoid tipping the unit over in the vehicle. Damage can occur to the
compressor or surrounding items if the compressor is tipped.
MOVING
When moving the compressor, grasp the handle and carry the
compressor as close to the body as possible.
WARNING: Risk of unsafe operation. Ensure proper footing and
use caution when carrying compressor to avoid a loss of balance.

PREPARATION FOR USE

Pre-Start Checklist (Fig. 1)
1. Ensure the On/Off switch (A) is in the OFF position.
2. Plug the power cord into the correct branch circuit receptacle.
See Voltage and Circuit Protection under Installation.
3. Ensure air tank is drained, see Draining Air Tank under
Maintenance.
4. Ensure the drain valve (H) is closed.
5. Ensure safety valve (G) is functioning properly, see Checking
Safety Valve under Maintenance.
6. Check
pump
under Maintenance.
CAUTION: Do not operate without oil or with inadequate oil. D
not responsible for compressor failure caused by inadequate oil.
7. Turn regulator knob (D) counterclockwise until fully closed. Ensure
WALT
e
regulated pressure gauge reads 0 PSI (0 kPa).
8. Attach hose and accessories.
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
9. Ensure all covers and labels are in place, legible (for labels) and
securely mounted. Do not use compressor until all items have
been verified.
WARNING: Risk of bursting. Too much air pressure causes a haz-
ardous risk of bursting. Check the manufacturer's maximum pressure
rating for air tools and accessories. The regulator outlet pressure must
never exceed the maximum pressure rating.
INITIAL SET-UP (FIG. 1)
WARNING: Do not operate this unit until you read and understand this
instruction manual for safety, operation and maintenance instructions.
BREAK-IN PROCEDURE
WARNING: Serious damage may result if the following break-in
instructions are not closely followed.
This procedure is required before the air compressor is put into
service for the first time and when the check valve or a compressor
pump/motor has been replaced.
1. Ensure the On/Off switch (A) is in the OFF position.
12
oil
level,
see
Compressor
Pump
Oil
WALT is
E

Publicité

Table des Matières
loading

Table des Matières