Commissioning; Switching On; Setting The Safety Limit Values; Function Shaking - IKA KS 3000 i Mode D'emploi

Masquer les pouces Voir aussi pour KS 3000 i:
Table des Matières

Publicité

Commissioning

Make sure before start-up of the equipment that the drain hose
leads into a drain!
For protection in transport, a strip of foamed material is inserted
between the shaker table and the inner face or the rear wall. This
must be removed before initial commissioning.
Check whether the voltage specified on the type plate matches the
mains voltage available. The power socket used must be earthed
(protective earth conductor contact). If these conditions are met,

Switching on

Note the load guideline values for the
WARNING
attachments prior to switching appliance
on (see „Attachments").
The appliance is switched on using the switch on the side of the
appliance. Once it has been switched on, all of the LEDs light up
briefly during the self test.
Device type
Safety limit
values
Tapping the Start/Stop keys or On/Off key starts the particular
functions.
The desired default values can be changed using the + or - keys.
Use the shift key  to switch from hour / minute mode to minu-
te / second mode.

Setting the safety limit values

If the Time ON/OFF key  is held down while „SAFE" is displayed, the safety limit values can be changed using the respective
up/down keys.

Function Shaking

Press  key to start or stop the shake function. The speed
can be adjusted during operation. The displayed value flashes
until the pre-set speed has been reached.
When the shaking function is started using button  , the timer
automatically starts measuring the time until the next switch-off.
Display fields
Operating mode
Software
version
max. ad-
max. ad-
justable
justable
speed
temperature
the device is ready to operate after plugging in the mains plug.
If these procedures are not followed, safe operation cannot be
guaranteed and/or the equipment may be damaged.
Observe the ambient conditions (temperature, humidity, etc.) listed
under Technical Data.
Main switch I/O
If the elapsed time exceeds the value of 100 hours, the display
switches from hour / minute mode
to hour mode
Only whole hours are displayed in hour mode.
The following sections contain detailed information about the
individual functions.
Note:
The shaking function can only be started when the cover is
closed. When the cover is opened, the shaker automatically
switches off the shaking and heating functions.
16

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ks 3000 ic

Table des Matières