Tools and Parts
Gather the required tools and parts before starting installation.
Tools needed
Tape measure
■
Flat-blade screwdriver
■
⁄
" (24 mm) combination
15
■
16
wrench
Pipe wrench
■
Channel lock pliers
■
Parts supplied
Gas pressure regulator
■
Burner grates: common (4), center (1)
■
Burner bases (5)
■
Burner caps (5)
■
Simmer cap
■
Clamp brackets (2)
■
2¹⁄
" (6.4 cm) clamping screws (2)
■
2
Foam tape seal
■
LP conversion kit - W10686634
■
Parts needed
Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See "Electrical Requirements" and
"Gas Supply Requirements" sections.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances. Do
not obstruct flow of combustion and ventilation air.
It is the installer's responsibility to comply with installation
■
clearances specified on the model/serial/rating plate. The
model/serial/rating plate is located on the underside of the
cooktop burner box.
Do not unpack the burner grates and bases until after the
■
cooktop is installed to avoid scratching the cooktop.
To eliminate the risk of burns or fire by reaching over heated
■
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
The cooktop should be installed in a location away from
■
strong draft areas, such as windows, doors and strong
heating vents or fans.
All openings in the wall or floor where cooktop is to be
■
installed must be sealed.
Cabinet opening dimensions that are shown must be used.
■
Given dimensions are minimum clearances.
Grounded electrical supply is required. See "Electrical
■
Requirements" section.
Proper gas supply connection must be available. See "Gas
■
Supply Requirements" section.
The gas and electric supply should be located as shown in
■
"Gas and Electric Connection Locations" in the "Location
Requirements" section so that they are accessible without
requiring removal of the cooktop.
INSTALLATION REQUIREMENTS
Marker or pencil
■
Pipe-joint compound
■
resistant to LP gas
Noncorrosive leak-detection
■
solution
IMPORTANT: To avoid damage to your cabinets, check with
your builder or cabinet supplier to make sure that the materials
used will not discolor, delaminate or sustain other damage.
Mobile Home - Additional Installation Requirements
The installation of this cooktop must conform to the
Manufactured Home Construction and Safety Standard, Title 24
CFR, Part 3280 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD Part 280). When such
standard is not applicable, use the Standard for Manufactured
Home Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this cooktop must conform with the
current standards CAN/CSA-A240-latest edition, or with local
codes.
Product Dimensions
A
A. *21" (53.3 cm)
B. *30" (76.2 cm) on 30" (76.2 cm) models
36" (91.4 cm) on 36" (91.4 cm) models
C. 3
/
" (8.3 cm)
1
4
*Metal tabs should not be bent during installation
Gas and Electric Connection Locations
D
A. Gas pressure regulator (supplied) - arrow pointed
toward cooktop
B. 3 prong grounding type outlet with correct polarity
C. Gas shutoff valve
D. 18" (45.7 cm) minimum
B
C
A
B
C
3