Press the the
decompression
(1) button.
Hold the front hand lever with one hand and press with your foot to the lateral pedal to the
floor.
Start Cable: Cable tighten until resistance can roll back and then forcefully put in a train.
If the engine according to the third Tightening does not start, open the choke slightly.
Falls der Motor nach dem 3. Anziehen nicht anspringt, Choke etwas öffnen.
The combi-switch after the first engine noises flammable placed in the
If the engine is running throttle lever (4) Press briefly to dislodge the lock button and the full
throttle position is changed to idle.
Leave for a few minutes without engine load.
When a load is always at max throttle. Hold speed!
13.1.2 Warm start
Press the ON-OFF switch to the ON position.
Combination switch (2) in the OPEN position on the right. Do not choke on a warm start.
Engine with pull starter start
13.1.3 Switch off
For a longer life of your engine you let the engine to idle for 3-5 minutes before turning off idle.
ON OFF switch to OFF position switch.
NOTE:
The length of the starter pull rope is 1.15 meters. Do not pull with great force. When all the rope
has been pulled, the rope is pulled with further train. In addition, it can also mean that the parts
are damaged.
Once you have pulled the rope, should you let it go immediately. One should continue to hold the
hand lever of the starter pull rope and lead it back down.
The rope should be straight up or down to reduce wear.
After the train of the starter pull cord you can roll it slowly.
At this time, when the gasoline engine is not started successfully, it is necessary to press the
button of the decompression valve again to restart.
ZIPPER MASCHINEN GmbH
www.Zipper-Maschinen.at
ZI-BTS350
OPERATION
ON-OFF switch
position.
24