Temperature for 1st switching point: Tmp1
The kiln heats up at the previously set heating rate (Rmp1) until reaching the tem-
perature set for the 1st switching point. By default, the temperature is entered in
degrees Celsius per hour.
Push the
or
key until the "Tmp1" LED indicator in the 1st dwell tem­
perature program section flashes. The display shows the value that has
been stored. Use the
or
key to enter a value between 20 and 1320°C.
Heating to end temperature: Rmp2
The kiln heats up at the rate set. By default, the rate is entered in degrees Celsius
per hour.
Push the
or
key until the "Rmp2" LED indicator in the 2nd heating ramp
program section flashes. The display shows the value that has been stored.
Use the
or
key to enter a value between 1 and 999°C/h or SKIP (heating
at full power).
Temperature for end temperature: Tmp2
The kiln heats up at the rate set until reaching the first dwell temperature. By default,
the rate is entered in degrees Celsius per hour.
Push the
or
key until the "Tmp2" LED indicator in the end temperature
program section flashes. The display shows the value that has been stored.
Use the
or
key to enter a value between 20 and 1320°C.
Dwell time at end temperature: t2
The kiln holds the end temperature for the time set. The dwell time ensures an even
heating of the fired products inside the kiln
Push the
or
key until the "t2" LED indicator in the dwell time at end
temperature program section flashes. The display shows the value that has
been stored. Use the
or
key to enter a value between 0.00 and 9.59
(hours.minutes).
Cooling or end of program: Rmp3
At the end of the dwell time, the kiln cools down either controlled (e.g. 200°C/h) or
uncontrolled (= SKIP). At 150 °C, the controller stops the temperature control and
the display shows "End" to indicate the end of firing.
Push the
or
key until the "Rmp3" LED indicator in the cooling or end
of program section flashes. The display shows the value that has been
stored.
8
8
Use the
or
key to enter a value between 1 and 999°C/h or SKIP (un­
controlled cooling).
Saving a program
The TC 304 automatically saves all the variable values of the firing curve.
The control unit stops the processing of the program if no values have been entered
for 30 seconds. The display indicates the room temperature.
As an alternative, press the "Start/Stop" key to start the desired program imme-
diately or use the mains switch to turn the control unit off.
Values that have been changed are saved automatically.
Appendix A: TC 304 Error and Event Messages
Error and event messages
The controller indicates particular events such as power failure, sensor malfunctions
or kiln errors and processes them accordingly.
The event codes are:
E-CODE A = Operational and controller errors
E-CODE B = Errors resulting from power failure
E-CODE C = Internal errors
E-CODE D = Hardware errors
The list below shows possible event messages and their meaning.
E A4
9
9