Menu 6. State; Menu 7. Counter Memory; Alarms; Level Fail Alarm - Bronpi Karina Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
5.2.7.

MENU 6. STATE

It involves a technical parameter that shows us the capacitive state.
5.2.8.

MENU 7. COUNTER MEMORY

By accessing menu 7 "Counter Memory" we will know the partial and total hours of the geared engine working, such as the number of
lightings.
5.3.

ALARMS

In case of an anomaly during the operation, the electronics of the tank intervenes and highlights the regularities that have taken place in the
different ways of operation, depending on the type of fault. The following alarms may appear:
5.3.1.

LEVEL FAIL ALARM

When the pellet level sensors installed in the boiler have an abnormal reading, such as that the minimum level is not recognized or has a
reading of fuel presence in the tank while the maximum level sensor indicates that the hopper is full, the alarm "Level Fail" will be shown. This
event may be caused for the break of one of the sensors or for the imbalance in the electronic card.
5.3.2.

EMPTY SILO ALARM

This alarm appears when the sensor of the auxiliary tank detects that the fuel load inside is low and it is not able to provide fuel to the boiler
hopper. To delete the alarm we must press button 3 for a few seconds and then we will restart it.
Alarm Code
Description
AL
FALLO NIVEL
AL
EMPTY SILO
OPERATING INSTRUCTIONS
120
Menu 05
T MAX
LOAD
Menu 07
MEMORY
COUNTER
FAILURE
LEVEL
Problem
Problem with level sensor.
The auxiliary tank has no fuel.
Possible solution
Check the connections of the different sensor or replace them.
Fill the auxiliary tank and restart the equipment.
21
1000 L AUXILIARY TANK