Programme 3: Monday (OFF), Tuesday (ON), Wednesday (ON), Thursday (ON), Friday (ON), Saturday (ON), and Sunday (OFF.)
-
Programme 4: Monday (ON), Tuesday (ON), Wednesday (OFF), Thursday (OFF), Friday (OFF), Saturday (OFF), and Sunday (ON.)
Thanks to this type of setting we can combine 2 different times throughout the days of the week, but always keeping in mind to not
superimpose the times.
5.2.3.4.

SUB-MENU 02.04. WEEKEND PROGRAMME

This setting has two independent times to start and stop, with the exception that it only applies to Saturday and Sunday. We must
take into account that the stop schedule will only work when the minimum level sensor has not started the system before the start
schedule takes place. To access to this setting we need to start from the following screen:
We must confirm that we want to access to this programme by pressing button 3 "SET", and the following screen will be shown:
We modify the value "OFF" and choose the start hour:
In this case we can define a specific hour of stop.
Finally, we introduce the times to start and stop to complete the desired setting up.
In case that you may want to set up just one time to start and stop, the options START 2 and STOP 2 should be "OFF".
It is also possible to schedule one automatic start hour START 1: 08:00 and manual stop hour STOP 2: "OFF". Or vice versa START 1: "OFF"
and a stop hour STOP 1: 22:00.
5.2.4.

MENU 3. SELECT LANGUAGE

See Boilers User's Manual.
5.2.5.

MENU 4. BUZZER MODE

See Boilers User's Manual.
5.2.6.

MENU 5. MAXIMUM TIME OF CHARGE

We can change the maximum working time of the geared engine in menu 05 and with buttons 1 and 2, considering that:
-
If during this period the pellet level in the boiler exceeds the maximum level established by the sensor, the geared engine will
automatically stop, ceasing the fuel feed on the boiler hopper.
-
If after this time the pellet level in the boiler has not reached the minimum established, the load time will restart as necessary to exceed
the minimum level.
OPERATING INSTRUCTIONS
ON
M - 2 - 3 - 03
MONDAY
PROG-1
M - 2 - 4
PROGRAMME
WEEKEND
OFF
M - 2 - 4 - 01
START
PROG - 1
12:00
M - 2 - 4 - 01
START
PROG - 1
20