Power Supply Cord Method – U.S. Only
■ If local codes do not permit the connection of a neutral ground
wire to the neutral wire, see "Optional 3-wire connection"
section.
■ A 4-wire power supply connection must be used when the
appliance is installed in a location where grounding through the
neutral conductor is prohibited. Grounding through the neutral
is prohibited for (1) new branch-circuit installations, (2) mobile
homes, (3) recreational vehicles, and (4) areas where local
codes prohibit grounding through the neutral conductors.
Power Supply Cord,
Four-wire electrical connection:
A
B
C
G
A. Spade terminals
with upturned ends
B. Neutral
C. 3/4" (19 mm)
UL-listed strain relief
Four-wire power supply cord must have four, No. 10 copper wires and match a four-wire
receptacle of NEMA Type 14-30R. The fourth wire (ground conductor) must be identified
by a green cover and the neutral conductor by a white cover.
5. Remove the center terminal block screw.
6. Remove the appliance neutral ground
7. Connect the ground wire of the power
8. Connect the neutral wire (white or center)
D
9. Connect the other wires to outer terminal
F
E
10. Tighten strain relief screws.
11. Insert tab of the terminal block cover into
D. Neutral (white)
E. Ring terminals
F. Ground wire
G. Ground prong
1. Disconnect power.
2. Remove hold-down screw and the terminal block cover.
3. Assemble 3/4" (19 mm) UL-listed strain relief (UL marking
on strain relief) into the hole below the terminal block opening.
Tighten strain relief screws just enough to hold the two clamp
sections together. Install power supply cord through the
strain relief.
4. Complete installation following instructions for your type of
electrical connection:
• Four-wire (recommended method)
• T hree-wire (if four-wire is not available)
wire from the external ground conductor
screw. Fasten under center terminal block
screw.
supply cord to the external ground
conductor screw. Tighten screw.
of the power supply cord under the center
screw of the terminal block. Tighten
screw.
block screws. Tighten screws.
slot of the dryer rear panel. Secure cover
with hold-down screw.
A
C
B
A. External ground conductor screw
B. Tab
C. Terminal block cover
D. Hold-down screw
A
A. Strain relief clamp sections
B. Dryer cabinet
C. Strain relief screws
A
G
F
E
A. External ground conductor screw
B. Appliance neutral ground wire
C. Center terminal block screw
D. Outer terminal block screws
E. Strain relief screw
F. Neutral (center wire)
G. Ground wire
D
B
C
B
C
D