Concept CPT273 Manuel D'utilisateur page 7

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

seTuP & oPerATioN
WARNING! Serious damage may result if the following break-in instructions are
!
not closely followed.
CAUTION: Do not attach air tool accessories or tools to open end of hose until
start up has been completed and unit checks OK.
1. Make sure the Off/Auto-On switch is in the "Off" position.
2. Turn the regulator knob counterclockwise until it stops.
3. Plug the power cord into the correct branch circuit receptacle.
4. Open the drain valve fully (counterclockwise) to permit air to escape and
5. Move the Off/Auto-On switch to "Auto-On" position. The compressor will
6. Run the compressor for 15 minutes. Make sure the drain valve is open and
7. After 15 minutes, close the drain valve (clockwise). The air receiver will fill to
oPerATioN oF Air ComPressor
!
NOTE: Become familiar with these controls before operating the unit.
= OFF/AUTO-ON SWITCH (C6): Turn this switch to "Auto-On" to provide auto-
= PRESSURE SWITCH (not shown): The pressure switch automatically starts
= REGULATOR: Controls the air pressure shown on the outlet pressure
= SAFETY VALVE (C1): If the pressure switch does not shut off the air com-
= OUTLET PRESSURE GAUGE (C4): The outlet pressure gauge indicates
= DRAIN VALVE (C7): The drain valve is located at the base of the air tank
= AIR COMPRESSOR PUMP (not shown): Compresses air into the air tank.
= CHECK VALVE (not shown): When the air compressor is operating, the
BeFore eACH sTArT-uP:
1. Move Off/Auto-On switch to "Off" and close the air regulator.
2. Turn the regulator knob counterclockwise until it stops.
3. Attach recoil air hose and accessories or air tool.
WARNING! Too much air pressure causes a hazardous risk of bursting. Check
!
the manufacturer's maximum pressure rating for air tools and accessories. The
regulator outlet pressure must never exceed the maximum pressure rating.
HoW To sTArT:
1. Move the Off/Auto-on switch to "Auto-On" (I) and allow tank pressure to build.
2. Turn the regulator knob clockwise until desired pressure is reached.
NOTE: To use the suggested pressure reading on the pressure gauge, wait until
the indicator aligns with the desired suggested pressure reading number.
3. The compressor is ready for use.
prevent air pressure build up in the air tank during the break-in period.
start.
there is minimal air pressure build-up in tank.
"cut-out" pressure and the motor will stop.
matic power to the pressure switch and "Off" to shut off the power.
the motor when the air tank pressure drops below the factory set "cut in"
pressure. It stops the motor when the air tank pressure reaches the factory-
set "cut out" pressure.
gauge. Turn knob (C2) clockwise to increase pressure and counter-clock-
wise to decrease pressure.
pressor at its "cut-out" pressure setting, the safety valve will protect against
high pressure by "popping out" at its factory set pressure (slightly higher than
the pressure switch "cut out" setting).
the air pressure available at the outlet side of the regulator. This pressure is
controlled by the regulator and is always less than or equal to the tank pres-
sure.
and is used to drain condensation at the end of each use.
Working air is not available until the compressor has raised the air tank pres-
sure above that required at the air outlet.
check valve is "open", allowing compressed air to enter the air tank. When
the air compressor reaches the "cut out" pressure, the check valve "closes",
allowing air pressure to remain inside the air tank.
Motor will stop when tank pressure reaches "cut out" pressure.
7