TROUBLESHOOTING
Problem
Possible causes
Product refuses
Product not plugged in
to start
Defective socket
Defective extension cable
Fluctuating
Pump sucking air
pressure
Valves dirty, worn out or
stuck
Pump seals worn out
Product stops
Fuse has blown
Incorrect mains voltage
Thermal sensor activated
Nozzle partially blocked
Product pulsating
Air in inlet hose/pump
Inadequate supply of mains
water
Nozzle partially blocked
Water fi lter blocked
Hose kinked
Product often
Pump/spray handle is leaking Bring the product to an authorized service centre for
starts and stops
by itself
Product starts, but
Pump/hoses or accessory
no water comes
frozen
out
No water supply
Water fi lter blocked
Nozzle blocked
No detergent
Nozzle adjusted to high
pressure
Tank is empty.
Solution
Plug in product.
Try another socket.
Try without the extension cable.
Check that hoses and connections are air tight.
Bring the product to an authorized service centre for
service or repair.
Bring the product to an authorized service centre for
service or repair.
Bring the product to an authorized service centre for
service or repair.
Check that the mains voltage corresponds to
specifi cation on the model tag.
Leave the cleaner for 15 minutes to cool down.
Clean the nozzle.
Allow the product to run with open trigger until
regular working pressure resumes.
Check that the water supply corresponds to the
specifi cations required (see model tag). Avoid using
long, thin hoses.
Clean the nozzle.
Clean the fi lter.
Straighten out hose.
service or repair.
Wait for pump/hoses or accessory to thaw.
Connect the water inlet port to a water supply.
Clean the fi lter.
Clean the nozzle.
Adjust to low pressure.
Fill the tank.