9. TECHNICAL DETAILS

Supply voltage:
Current
consumption
transmitter
(TX):
Current consumption receiver (RX):
Outputs
Output current (for all loads):
Output voltage ON min.:
Output voltage OFF max.:
Leakage current:
Capacitive load (pure):
Resistive load (pure):
Reaction time:
Transmitter, wavelength:
Resolution:
Operating range:
Category:
Operating temperature:
Storage temperature:
Humidity:
Protection class:
Protection type:
Ambient brightness:
Vibration:
Shock resistance:
Reference standards:
Housing material:
Material of upper and lower cover:
Lens material:
Connections:
Cable runs:
Weight:
* = The same specifications must be met if a longer cable is used.
** Protection class
Protective earth
Symbol for protective earth
Protection through low voltage power supply (SELV
and PELV)
31
PSEN op2H Series
24 Vdc ± 20% (SELV/PELV)
50 mA max. / 1 W
90 mA max. (without load) / 2.5 W
2 PNP outputs
Short circuit protection max:1.4 A at 55°C
min: 1.2 A at 0°C
500 mA max. (at a single output)
Vdc – 1 V
0.2 V
0.65 mA
100 nF max
60Ω min.
24 ms at maximum length
(See table: "Available models")
Infra-red (880 nm)
30 mm
0.2...15 m
Type 2
-0...+ 55 °C
-25...+70 °C
15...95 % (non-condensing)
Class 1 / Class 3 (** see note)
IP65 (EN 60529)
IEC-61496-2
Amplitude 0.35 mm, frequency 10 ... 55 Hz, 20 sweeps
for all axes; 1 octave/min., (EN 60068-2-6)
16 ms (10 G) 1.000 shocks for all axes
(EN 60068-2-29)
EN 61496-1; prEN 61496-2
Varnished aluminium (yellow RAL 1003)
PBT
PMMA
4-pin M12 connector on TX
5-pin M12 connector on RX
500 m max. *
(at 100 nF capacitive load and Vdc = 24 V)
12-core (in accordance with EN 50044, EN 60947-5-2)
Core Ø = 32 x 0.1mm, external Ø = 5 mm
1 kg max/m of overall height
Class 1
Class 3
Mandatory
Not permitted
Mandatory
Not permitted
Recommended
Mandatory