Installing Several Adjacent Safety Light Curtains - Pilz PSEN op2H Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

PSEN op2H Series
2.2.3.

Installing several adjacent safety light curtains

If it is necessary to install several safety devices in adjacent areas, you
will need to ensure that the transmitter on one device cannot interfere
with the receiver on another.
To prevent this, the devices will need to be installed conversely or
must be separated via screening (opaque surface).
Fig.10 gives an example of an installation that could lead to
interference, plus two correct installations.
NO
YES
YES
Instruction Manual
Fig. 10
14