Diagnostic Function; Function Indicators - Pilz PSEN op2H Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Operating Manual

7. DIAGNOSTIC FUNCTION

7.1. Function indicators

4 LEDs on the receiver and 2 LEDs on the
transmitter
provide
the
information about the operating status of
the SAFEasy device. (Fig. 19).
LED SAFE/BREAK:
GREEN LED
SAFE is lit; indicates that
the transmitter and receiver are aligned
and the protected field is clear. The
outputs are ON.
RED LED
BREAK is lit; indicates that
the transmitter and receiver are not
aligned or an object is breaking the
protected field. The outputs are OFF.
LED HIGH ALIGN: (yellow) is unlit; indicates optimum alignment
between the last transmitter optic and the corresponding receiver
optic (top beam on the device).
ED LOW ALIGN: (yellow) is unlit; indicates optimum alignment
between the first transmitter optic and the corresponding receiver
optic (bottom beam on the device).
The key to the LEDs on the transmitter (TX) is as follows.
LED SAFE (yellow): is lit; indicates that the unit is transmitting
correctly.
LED POWER ON (green): is lit; indicates that power supply to the
device is correct.
27
PSEN op2H Series
user
with
Fig. 19

Publicité

Table des Matières
loading

Table des Matières