7. Commissioning/operation
B5
Direction buttons:
You can press any of the movement buttons singly or
together. The arrows on the buttons show the respec-
tive direction of movement.
Driving forwards
Both drive units pull forwards with full
power.
Turn towards the right front
Only the left drive unit pulls forwards
with full power. The right drive unit is
blocked.
Turn towards the left front
Only the right drive unit pulls forwards
with full power. The left drive unit is
blocked.
Driving backwards
Both drive units pull backwards with
full power.
Turn towards the right rear
Only the left drive unit pulls backwards
with full power. The right drive unit is
blocked.
Turn towards the left rear
Only the right drive unit pulls back-
wards with full power. The left drive
unit is blocked.
Left turn on the spot
The right drive unit pulls forwards with
full power. The left drive unit pulls
backwards with full power.
Right turn on the spot
The left drive unit pulls forwards with
full power. The right drive unit pulls
backwards with full power.
Arc towards the front right
The left drive unit pulls forwards with
full power. The right drive unit pulls
forwards with reduced power.
Arc towards the front left
The right drive unit pulls forwards with
full power. The left drive unit pulls
forwards with reduced power.
Arc towards the rear right
The left drive unit pulls backwards with
full power. The right drive unit pulls
backwards with reduced power.
Arc towards the rear left
The right drive unit pulls backwards
with full power. The left drive unit pulls
backwards with reduced power.
Buttons for automated swivelling on
and swivelling off. These have no
function in the easydriver BASIC
version.
The cable connections of the right or left drive unit to
the base station and the motor must be checked and
reversed as required (see connection plan) when the
manoeuvring movements do not correspond to the
symbols shown on the remote control.
It is essential to switch OFF the main switch and to
separate the base station from the voltage supply be-
fore performing any work.
Never swap the plus (+) and minus (-)
connection of the voltage supply!
GB9