Nightlight level
The controller recognizes "day" and "night" based on the solar PV array open circu it voltage. The d aylight threshold can
be modified according to the requirements of the local conditions and the solar PV array used.
To find the exact values, we recommend measuring the PV solar array "open circuit voltage" at twilight and when the
controller is expected to switch the loads "on" or "off". This value (the closest setting available) can then be set accordin g
to the description presented in the programming section.
Technical Data
Note: The voltage levels before/after the slash are valid for 12 V and 24 V systems respectively.
Technical Data
System volt age
Max. ch arge current
Max. load current
Max. usable PV power
Max. PV array p ower
Power conversion efficiency
Float charge
Main charge
Boost charge
Equalization charge
Overvoltage protection
www.phocos.com
Open circuit volt age curve of solar array
CIS-N-MPPT 100/30
12/24 V auto recognition
30 A*
30 A*
450 W (12 V system), 900 W (24 V system)
675 Wp (12 V system), 1350 Wp (24 V system)
Up to 98%
13.8/27.6 V (25 ° C)
14.4/28.8 V (25 ° C), 0.5 h daily
14.4/28.8 V (25 ° C), 2 h, activation: battery volt age < 12.3/24.6 V
14.8/29.6 V (25 ° C), 2 h, activation: battery volt age < 12.1/24.2 V
(at least every 30 days)
15.5/31.0 V
1 7 |
P a g e