Nightlight Function - Phocos CIS-N-MPPT 100/30 Manuel De L'utilisateur

Masquer les pouces Voir aussi pour CIS-N-MPPT 100/30:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30

Nightlight Function

The CIS-N-MPPT 100/ 30 controller comes with a sophisticated nightlight function. It controls the load output at night
and also is widely programmab le.
3 operating modes are available: Standard Controller, Dusk to Dawn and Evening/Morning.
"Middle of night" is automatically detected as the midpoint between dusk and d awn; no setting of a clock is required. It
may take several d ays until the controller has "learned" the middle of the night precisely. "Middle of night" may be
different from 12:00 midnight depending on your location/longitude.
The controller recognizes day and night based on the solar array open circuit volt age.
The day/night threshold can be m odified according to your local light conditions and the type of solar array used.
Dimming Function
Output voltage 0 V t o 10 V relative to b attery minus pole (ad just step 1 V, 3% t olerance)
Impedance 1,000 Ohm
Load hours (load 1 on CIS-CU case printing) and Dimming hours (load 2 on CIS-CU case printing) work together
to effect the dimming function:
Load hours
Dimming hours
Dimming output voltage
Corresponding relationship of 'Output voltage' and 'Dimming value'
Output voltage
0 V
Dimming
0%
value*
* : + /- 3% tolerance
www.phocos.com
No dimming
on
on
10 V
1 V
2 V
3 V
10%
20%
30%
Dimming is on
on
off
Voltage prop ortional t o
adjusted dimming value
4 V
5 V
6 V
40%
50%
60%
Load off
off
N/A
0 V
7 V
8 V
9 V
70%
80%
90%
1 4 |
P a g e
10 V
100%