Phocos CIS-N-MPPT 100/30 Manuel De L'utilisateur page 13

Masquer les pouces Voir aussi pour CIS-N-MPPT 100/30:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
Mains and charging current risks
Make sure the cables are always connected to the correct terminal. An electrical shock can be lethal. In general, any
electric shock can be d angerous to your health.
CE labeling
The product is CE compliant.
Connecting and Grounding
Connect wires in indicated order 1 2 3 4 5 6 7 to avoid any installation faults
To avoid any damaging voltage on the wires, first connect the wire t o the controller, then to the battery, p anel or
to the load
Minimum recommended wire size: 10 mm ²
Make sure the wire length between battery and controller is as short as possible
Be aware that all negative wires of CIS-N-MPPT 100/ 30 are connected together and therefore have the same
electrical potential. If any grounding is required further to the casing , alw ays d o th is on the negative wires.
Grounding of the casing is done b y the grounding post on the left side.
The controller w arms up during operation, and should therefore be installed on a non flammable surface only.
When connecting inductive loads (mot ors, relays, etc.) a freewheel diode must b e connected in parallel t o the
loads in the reverse biased direction.
Inverters should always b e connected directly to the b attery due to their high inrush currents.
Function
Negative battery terminal
Positive b attery terminal
Negative panel terminal
Positive p anel terminal
Negative load terminal
Positive load terminal
Dimming signal terminal
www.phocos.com
Wire size (cross section)
Cable m arker
COMMON -
BATTERY +
COMMON -
SOLAR +
COMMON -
LOAD +
---
3.3 mm
2
3.3 mm
2
3.3 mm
2
3.3 mm
2
3.3 mm
2
3.3 mm
2
0.25 mm
2
1 2 |
Color
Black
Red
Black
Yellow
Black
Orange
Black
P a g e

Publicité

Table des Matières
loading

Table des Matières