The counters come with a frame-platf orm in wood fi xed to the base for transportati on with forklift s:
Features of the
Use a forklift :
- with suitable specifi cati ons in compliance with applicable standards
forklift
- NOT worn/damaged
stacker crane
- manual or electrical suitable for lift ing the counter, with a nominal capacity
- with compliant and NON worn cables
Safe handling
• make sure there are no foreign objects within the handling area
• always place the lift ing brackets in the indicated points
(how to pro-
• always introduce the brackets completely
ceed)
• balance the weight of the counter so as to ensure that the load remains bal-
i
DO NOT use transportati on procedures other than those indicated.
12. Storage
Remedy
• the counters must be stored indoors, with a temperature ranging between
• before storing the counters, check that the packing is intact and that it does
What to avoid
13. Installati on and environmental conditi ons
DANGER! Live parts. Electrocuti on.
The norms and laws in force must be complied with during installati on and use.
WARNING!
Before carrying out any operati on, take all possible precauti ons to prevent injury to the
operator, use the individual Personal Protecti on Equipment provided (chapter 3).
Installati on is reserved to technicians trained and authorised by the body specifi ed in the
contract (manufacturer/dealer/distributor)
i
- It is the responsibility of the customer to prepare the installati on area
- Changes to the setup described here must be authorized by ARNEG S.p.A.
The counter can be delivered packed as follows:
• with frame in wood fi xed to the base and nylon casing blocked by straps (standard) (Fig.4)
• with a cardboard casing (on request) (Fig.5)
• with wooden crate (on request) (Fig.6)
05060180 00 03-04-2019
Mini Ankara Twin 4P-Ankara Twin 4P-Mini Arka Twin 4P-Arka Twin 4P
greater than or equal to 1000 kg
anced (Fig.9)
WARNING! Heavy object. Crushing
Observe the indicati ons regarding safe handling
Dragging. Collapsing/deformati ons/tearing
DO NOT drag/push the counter
DO NOT use the glass panels for att achment/support/grip
Observe the indicati ons regarding safe handling
-25°C and +55°C and a humidity of between 30% and 90%.
not display any defect that may compromise preservati on of the counters.
UV rays. Permanent deformati on of plasti c materials / damage to cabi-
net components.
DO NOT store the counters in uncovered areas exposed to atmospheric
agents and to direct sunlight.
English