Table Des Matières; Technical Data; Technical Drawing - BWT AQA nano Notice De Montage Et D'utilisation

Appareil anti-calcaire
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

GB

12. Technical Data

Connection nominal diameter
Connection thread
Limescale protection up to max. 20°dH
Limescale protection capacity
Operating pressure PN
Temperature water inflow max.
Temperature environment max.
Temperature boiler max.
Dimensions of device & connection
dimensions:
Width x height
Fitting length (with screw connections)
Clearance: Wall middle of pipe
Weight
Cable length
Mains connection
Electrical connected rating
Capacity stand-by operation
Energy consumption per m
3
water
Type of protection
* depending on water quality
** country-specific
12
AQA nano
DN
25
outside thread
1"
m
3
1.5
25
0,6
m
3
110 ± 10*
months max.
12
16
30
40
80
mm
mm
234
mm
80 to 100
kg
ca. 11
mm
1000
230/50, 110/60 **
5.5
1.8
kWh
0.018
IP 54

13. Technical Drawing

AQA nano
Flow direction left to right
AQA nano
Flow direction right to left
GB
13
10
10

Publicité

Table des Matières
loading