JB Systems Lunx II LED Mode D'emploi page 5

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
ENGLISH
Slave Mode
Used to make the slave unit work in opposite to the master or to work in complete sync.
 Press the MENU button until
is shown on the display.
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP button to select
(normal) or
 Once the mode is selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again for about 2 seconds.
Sound Mode
The unit works to rhythm of the beat when used in standalone or master/slave mode
 Press the MENU button until
is shown on the display.
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP button to select
or
 Once the mode has been selected, press the ENTER button save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again for about 2 seconds.
Blackout Mode
Blackout mode: when no DMX-signal is detected, the unit goes in blackout and waits for the DMX-
signal.
No blackout mode: when no DMX-signal is detected, the unit automatically switches to standalone
mode.
 Press the MENU button until
is shown on the display.
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP button to select
(blackout on) or
 Once the mode has been selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again for about 2 seconds.
Pan Inversion
Normal: Panning movement is not inversed.
Pan inversion: Panning movement is inversed
 Press the MENU button until
is shown on the display.
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP button to select
(normal) or
 Once the mode has been selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again for about 2 seconds.
Tilt Inversion
Normal: Tilt movement is not inversed.
Tilt inversion: tilt movement is inversed
 Press the MENU button until
is shown on the display.
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP buttons to select
(normal) or
 Once the mode has been selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again for about 2 seconds.
JB SYSTEMS
®
OPERATION MANUAL
(2 light show) mode.
mode.
(blackout off) mode.
(pan inversion) mode.
(tilt inversion) mode.
5/63
ENGLISH
Display on: display is always on.
Display off: display is off when not used.
 Press the MENU button until the display shows
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP buttons to select
 Once the mode has been selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again for about 2 seconds.
Display normal: display is readable when the unit is on the floor.
Display inversion: display is readable when the unit is mounted upside down.
 Press the MENU button until
 Press the ENTER button to toggle between
 After about 8 seconds your choice is automatically saved.
Used to help you adjusting the focus of the light beam and gobos.
 Press the MENU button until
 Press the ENTER button so the unit goes to the "tilt 90°" position.
 Press the ENTER button so the unit goes to the "pan 0°" position.
 Press the ENTER button so the unit goes to the "pan 90°" position.
 Press the ENTER button so the unit goes to the "pan 180°" position.
 Press the ENTER button so the unit goes to the "pan 270°" position.
In the Previous 5 steps you are able to adjust the focus with the UP/DOWN buttons on the unit (the display
shows the current focus status).
Attention: please note that you can only set an "average focus" for all 5 positions, so it is not possible to set
the focus perfectly sharp for all directions.
 To go back to the functions press the MENU button.
Used to activate the internal "self-test" program which shows all possibilities of the unit.
 Press the MENU button until
 Press the ENTER button to start the internal self-test program.
 To go back to the functions press the MENU button.
Used to show the temperature inside the unit
 Press the MENU button until
 Press the ENTER button and the temperature of unit will show on the display.
 To go back to the functions press the MENU button again.
Used to show the number of working hours of the unit.
 Press the MENU button until
 Press the ENTER button to show the number of working hours in the display.
 To go back to the functions press the MENU button.
Used to show the software version that is installed in the unit
 Press the MENU button until
 Press the ENTER button to show the software version on the display.
 To go back to the functions press the MENU button.
LYNX-II
JB SYSTEMS
Led Display
.
(display always on) or
Display Inversion
is shown on the display. (normal display)
(normal display) and
Focus Adjust
is blinking on the display.
Self-Test
is blinking on the display.
Temperature inside the unit
is blinking on the display.
Fixture Hours
is blinking on the display.
Software version
is blinking on the display.
6/63
®
OPERATION MANUAL
(display off when not used).
(display inversion).
LYNX-II

Publicité

Table des Matières
loading

Table des Matières