To start an engine with vapor lock
Vapor lock occurs when the fuel in the fuel line or
carburetor vaporizes because of increased heat.
The product may have vapor lock if it does not restart in
an ambient temperature of more than 35°C (95°F) and it
has been shut off for 15-45 minutes.
1. Push the air purge bulb again and again for 10-15
seconds.
2. Move the choke lever to the HALF CHOKE position.
3. Pull the starter rope handle quickly until the engine
runs.
4. Let the engine warm up for 3 minutes at idle speed.
5. Move the choke lever to the NO CHOKE position.
To stop the engine
•
Push and release the engine STOP switch. The
switch automatically returns to the ON position. Wait
7 seconds before you try to restart the product to
make sure that the switch resets.
To adjust the VX
1. Align the correct slot (A or B) on the outer VX
blower tube with the tab (C) on the inner tube. (Fig.
34)
Note: You cannot see the tab when the tubes are
assembled. You must feel the position of the tab as
you move the outer tube.
Note: Engage the tab in position "A" for a large
blower opening. A large blower opening moves wide
areas of dry leaves and other unwanted material.
Engage the tab in position "B" for a small blower
opening. A small blower opening makes air flow
faster to clean cracks and edging and to move heavy
material such as wet leaves.
2. Turn the outer tube as shown to disengage the tab
from the slot. (Fig. 35)
3. Move the outer tube along the inner tube to change
the position. (Fig. 36)
4. Turn the outer tube as shown until the tab is fully
engaged at the end of the correct slot location. (Fig.
37)
WARNING: Read and understand the safety
chapter before you clean, repair or do
maintenance on the product.
Maintenance schedule
Make sure that you obey the maintenance schedule.
The intervals are calculated from daily use of the
product. The intervals are different if you do not use the
12
™
blower tube
Operation position
•
Blower (Fig. 38)
•
Vacuum (Fig. 39)
To vacuum
Before you vacuum, put on the necessary safety
equipment.
•
During operation of the blower the collection bag
must be held by the shoulder strap. The strap must
be worn on the top of the shoulder.
™
•
Start the blower. Obey the instructions in the start
and stop section
the safety instructions
To empty the collection bag
1. Stop the product.
2. Open the zipper on the side.
3. Empty the collection bag.
4. Close the zipper.
Maintenance
product each day. Only do the maintenance work that is
found in this manual. Speak to an approved service
center about other maintenance work not found in this
manual.
Daily maintenance
•
Clean the external surfaces.
•
Examine the speed control and the throttle trigger
function. Replace damaged parts.
WARNING: Make sure that the collection
bag is not damaged and that the zipper is
closed before use. Do not use a bag that is
damaged. This prevents injury caused by
flying debris. Left hand operation increases
the risk. Do not let your body touch the
exhaust outlet area.
WARNING: Do not start the blower if the
inlet cover is open or damaged (except if the
vacuum tube is fitted).
To start and stop on page 11 . Read
Safety on page 7 .
WARNING: Always examine the collection
bag. Make sure that it is not damaged and
that the zipper is closed before use. Do not
use a damaged bag. There is a risk of injury
because of flying debris. Be careful if left
hand operation is applied. Do not touch the
exhaust outlet area.
728 - 009 - 13.11.2020