8.3 Pulse input function module

Module for two additional meters
Pulse input 1 is marked as "I1- ", input 2 with "I2 - ".
Pulse inputs can be programmed (IZAR@Mobile 2) with a value: 1, 2.5,
10, 25, 100, 250, 1000, 2500 l per pulse.
ƒ
Pulse transmitter must be electrically isolated, e.g. Reed contact
ƒ
Possible units are all the energy units available in the meter, the vol-
ume unit m³ or no unit.
input frequency
Min. pulse duration
input resistance
Terminal voltage
cable length
Data is accumulated separately
in registers; can be read in the
display as IN1 and IN2 and can
be transferred via the commu-
nication facility.
Français
Español
≤ 8 Hz
10 ms
2.2 MΩ
3 VDC
to 10 m