Energy meters are measuring devices and must be handled with care. To
protect against damage and soiling, they should only be unpacked imme-
diately prior to installation.
Transport
The transport of the meter is permitted only in the original package.
When sending wireless measuring instruments / components by
air, disable the wireless (place in aircraft mode) before shipping.
3.
Calculator Installation
ƒ
Depending on the design and application (heat or cooling meter),
the calculator is installed in either the hot or cold line of the system.
ƒ
Depending on the version, the integrator is programmed according
to the associated volume measurement part for the use in inlet or
outlet. The installation position is displayed in the info loop 3.5 (see
"Information loop (3)" on page 39) and, if necessary, also by means
of a pictogram.
Inlet
ƒ
Make sure the meter is installed sufficiently far away from possible
sources of electromagnetic interference (switches, electric motors,
fluorescent lamps etc.).
ƒ
If possible install the cables of the assigned flow sensor together with
the cables of the temperature sensor freely suspended (not bundled
- antennae effect) with sufficient distance to electromagnetic interfer-
ence sources.