1.
General
This guide is intended for trained specialised personnel. Therefore, it does
not include basic working steps.
The seal on the energy meter must not be damaged!
A damaged seal will result in immediate invalidation of the fac-
tory warranty and verification. The cables supplied with the
meter must neither be shortened, extended nor changed in any
other way.
The regulations on the use of energy meters must be observed!
The installation must only be carried out by a specialist instal-
lation or electrical company. The personnel must be trained in
the installation and handling of electrical equipment and be cog-
nisant of the Low Voltage Directive.
Medium
water, as per AGFW Instruction Sheet FW510.
If water additives are used (e.g. corrosion protection), the user
must make sure that the corrosion resistance is adequate.
ƒ
Optional also as a separate variant for the medium Tyfocor LS (see
loop 3) available.
ƒ
The medium temperature is specified as 5 ... 130 °C (150 °C)
ƒ
The temperature range depends on variant and nominal size.
ƒ
The exact temperature range is shown on the type plate.
ƒ
The operating/ambient conditions are 5 to 55 °C; IP 54/64; 93 % rel.
humidity.
ƒ
Ambient temperatures below 35 °C have a positive effect on battery
lifetime.
Pipeline insulation
In the case of the pipeline insulation, the housing with the elec-
tronics must remain free.
Detailed user guide available at https://www.diehl.com/metering/en/
support-center/download-center/. It must be observed without fail.
The IZAR@Mobile 2 software is used for readout/parametrization and is
obtainable on the internet at:
https://www.diehl.com/metering/en/support-center/download-center/