English
► Cover the text field of the warning
sign [1-11] with the supplied adhesive label
in your country's language.
► Insert the plug [1-1] at the cover plate (see
figure [1a]).
► Place a filter bag or safety filter bag in the
dirt trap in line with legal requirements (see
section 7.7, 7.8).
► Replace the top section [2-1] and close the
locking clips [2-2].
► Attach the cord holder to the reverse of the
mobile dust extractor (see figure [3]).
► Connect the suction hose to the machine.
6.2
Switching on/off
► Insert the mains plug into an earthed sock
et.
WARNING
Risk of injury from tools starting up unex
pectedly
► Before setting the switch to the "AUTO" or
"MAN" position, make sure that the con
nected tool is switched off.
The switch [1-10] serves as an on/off switch.
"0" switch position
Appliance socket [1-5] is disconnected from the
power, mobile dust extractor is switched off.
"MAN" switch position
Appliance socket [1-5] is connected to the pow
er, the mobile dust extractor starts.
"Auto" switch position
Appliance socket [1-5] is connected to the pow
er, the mobile dust extractor starts when the
connected tool is switched on.
7
Settings
7.1
Adjusting the hose diameter
► Adjust the hose diameter adjuster [1-8] to
match the diameter of the connected hose.
This ensures that the air speed in the ex
tractor hose is measured correctly (see
section "Volumetric flow monitoring").
18
7.2
Connecting electric power tools
WARNING
Risk of injury
► Observe the maximum appliance socket
connected load (see chapter "Technical da
ta")
► Switch off the electric power tool.
► Connect the electric power tool to the appli
ance socket [1-4].
7.3
Connecting pneumatic tools
WARNING
Risk of injury
► Switch off the air tool.
If the compressed air module [1-3] (496141) is
installed, the automatic switch-on function of
the mobile dust extractor also works in combi
nation with pneumatic tools.
We also recommend installing the VE service
unit (495886). The service unit filters and lubri
cates the compressed air and enables an ad
justment of the air pressure. An IAS adapter
(454757) is available to connect Festool pneu
matic tools to the IAS system.
The operating pressure of the tool must be
6 bar for the automatic switch-on unit to func
tion correctly.
7.4
Adjusting the suction power
► at the rotary knob [1-9].
7.5
Applying the brake
Folding out the black brake lever [1-15] pre
vents the mobile dust extractor from rolling. To
achieve this, lift the front end of the mobile dust
extractor slightly and push the black brake lev
er downwards until it latches into place. Push
the green lever [1-14] to release.
7.6
Temperature cut-out
A temperature cut-out switches the mobile dust
extractor off when it reaches a critical tempera
ture to prevent overheating.
► A temperature cut-out switches the mobile
dust extractor off when it reaches a critical
temperature to prevent overheating.
► Switch off the mobile dust extractor, allow
to cool for about 5 minutes then switch on
again.
Not possible to switch on: contact Festool