Toshiba R410 Manuel D'installation page 27

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

▼ In case of FE/FD without setting
Single port type FS unit
Piping
Indoor unit
Control wiring
between indoor
Remote control
unit and FS unit
(Within 49 ft
(15 m))
Group control
Multi port type FS unit
Piping
Indoor unit
Remote control
Group control
51-EN
1122001201_EN FR.indd 26
1122001201_EN FR.indd 26
▼ In case of FE/FD with setting
Single port type FS unit
Piping
Indoor unit
Control wiring
Remote control
between indoor
unit and FS unit
(Within 49 ft
(15 m))
Group control
Group control
Multi port type FS unit
Piping
Indoor unit
Remote
control
Group control
Group control
Single port type FS unit
Piping
Indoor unit
Control wiring
between indoor
Remote
unit and FS unit
control
(Within 49 ft (15 m))
Group control
Multi port type FS unit
Piping
Indoor unit
Remote
control
Group control
◆ [ Set up example ]
[ 0E ] : Group setting
0 : Individual (Factory default)
1 : Group
[ 14 ] : Group Address
0 : Individual
1 : Header unit
2 : Follower unit
[ FE ] : Branching system address (1~64)
• Should not be duplicate in one system
• Factory default : 99
[ FD ] : Priority operation mode
0 : Heating prioritized (Factory default)
1 : Cooling prioritized (The cooling is
prioritized even if setting only one unit in
one branching)
< In case of connecting one indoor unit>
Single port type FS unit
Piping
Indoor unit
Control wiring
between indoor
Remote
unit and FS unit
control
(Within 49 ft (15 m))
[ 0E ] : It is not necessary to set up
[ 14 ] : It is not necessary to set up
[ FE ] : It is not necessary to set up
[ FD ] : It is not necessary to set up
Multi port type FS unit
Piping
Indoor unit
Remote
control
[ 0E ] : It is not necessary to set up
[ 14 ] : It is not necessary to set up
[ FE ] : It is not necessary to set up
[ FD ] : It is not necessary to set up
– 26 –
<In case of connecting one group operation of
indoor units>
Single port type FS unit
Piping
Indoor unit
Control wiring
between indoor
Remote control
unit and FS unit
(Within 49 ft
(15 m))
Group control
[ 0E ] :
1
1
1
[ 14 ] :
1
2
2
[ FE ] :
It is not necessary to set up
[ FD ] :
It is not necessary to set up
Multi port type FS unit
Piping
Indoor unit
Remote control
Group control
[ 0E ] :
1
1
1
[ 14 ] :
1
2
2
[ FE ] :
It is not necessary to set up
[ FD ] :
It is not necessary to set up
<In case of connecting two group operations of
indoor units>
Single port type FS unit
Piping
Indoor unit
Control wiring
Remote
between indoor
control
unit and FS unit
(Within 49 ft
Group control
Group control
(15 m))
[ 0E ] :
1
1
1
1
[ 14 ] :
1
2
1
2
[ FE ] :
1
1
1
1
[ FD ] :
0
0
0
0
Multi port type FS unit
Piping
Indoor unit
Remote
control
Group control
Group control
[ 0E ] :
1
1
1
1
[ 14 ] :
1
2
1
2
[ FE ] :
1
1
1
1
[ FD ] :
0
0
0
0
9/2/16 1:30 PM
9/2/16 1:30 PM
EN
FR
52-EN

Publicité

Chapitres

Table des Matières
loading

Table des Matières