Inserting/Replacing The Battery; Battery State Of Charge; Switching On And Off; Operating Modes - Flex ALC 3/360-G/R 10.8 Notice D'instruction D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
it in vehicles for a long time. In case of
large variations in temperature, allow the
measuring tool to adjust to the ambient
temperature before putting it into operation.
In case of extreme temperatures or variations
in temperature, the accuracy of the measuring
tool can be impaired.
Avoid heavy impact to or falling down
of the measuring tool. After severe
exterior effects to the measuring tool, it is
recommended to carry out an accuracy check
(see "Accuracy Check of the Measuring Tool",
page XX) each time before continuing to
work.
Switch the measuring tool off during
transport. . When switching off, the levelling
unit is locked. Else it can be damaged in case
of intense movement.
Before switching on the
measuring tool
Unpack the plane laser level and check that
there are no missing or damaged parts.
NOTE
The batteries are not fuly charged on delivery.
Prior to initial operation, charge the batteries
fully. Refer to the charger operating manual.

Inserting/replacing the battery

■ Press the charged battery 10 into the power
tool until it clicks into place. (Fig. C1)
■ To remove, press the release button (1.)
and pull out the battery (2.) (Fig. C2)
CAUTION!
When the device is not in use, protect the
battery contacts. Loose metal parts may short-
circuit the contacts; explosion and fire hazard!

Battery state of charge

■ Press the button to check the state of
charge at the state of charge indicator
LEDs(8). (Fig. D)
■ The indicator goes out after 5 seconds.
■ If one of the LEDs flashes, the battery must
be recharged. If none of the LEDs light up
after the button is pressed, the battery is
faulty and must be replaced.
18

Switching On and Off

WARNING!
Do not point the laser beam at persons or
animals and do not look into the laser beam
yourself, not even from a large distance.
CAUTION!
Do not leave the switched-on measuring tool
unattended and switch the measuring tool off
after use. Other persons could be blinded by
the laser beam.
■ Rotate the locking rotary knob (7) to the " "
position according to the arrow in the figure (Fig. E).
■ The tool is turned on and get into
automatic balance mode. Immediately
after switching on, the measuring tool
sends laser beams out of the exit openings
(1). Default the horizontal laser H is only
turned on (Fig. F).
■ Rotate the locking rotary knob (7) to the
" " position according to the arrow in the
figure to turn off the tool (Fig. E).

Operating Modes

The measuring tool has several operating
modes between which you can switch at any
time. These are for:
Generating a horizontal laser plane
Generating a vertical laser plane,
Generating two vertical laser planes,
Generating a horizontal laser plane as
well as two vertical laser planes.
After you switch it on, the measuring tool
generates a horizontal laser plane. To
change the operating mode, press the key "
horizontal laser line (3) " or " vertical laser line
(4) ".
CAUTION!
Select the appropriate mode before using the
tool.
The position of laser maybe changes if
move or vibrate the tool while it is being
used.
Select the laser mode
Press the key " horizontal laser line (3) " or "
vertical laser line (4) " to select a specific laser
projection mode whether in auto-leveling mode
or lock mode.
ALC 3/360-G/R 10.8

Publicité

Table des Matières
loading

Table des Matières