14 Place the previously dismantled
lower plat unit on a flat surface,
remove the upper plate (1), remove
the ratchets (2) and place them in
their new housing as indicated in
figure B.
Rotate the spring (3) by 180°..
15 A) Remove the plugs that seal the frame
holes;
B) Position the previously prepared plate in
correspondence with the frame holes..
16 A) Remove the upper plaque in nylon
A) Remove the upper nylon plate
16
from the cabinet riser.
from the cabinet upright
B) Using a bit of . max 9 mm, drill in
B) Fit the nylon plate in the new
correspondence with the predisposed
position using the relative screw.
hole on the left side, so as to create a
housing for the pin of the upper hinge
Avoid off-axis or inclined holes. Drilling
depth: min.18 mm max 24 mm.
C) Re-position the nylon plaque in its
new position using the respective
screws..
17 At this point, re-mount the now left-handed
door, making sure to first insert the upper
hinge in the hole previously created and to
subsequently position it slowly in such a way
as to insert the lower pin in the respective hole
of the lower plate unit. As in dismantling, if
difficulties are encountered,.
18 Restore the electric connection, taking care
to rotate the plaque (1) by 180° so that the
words
"left door" appear on the upper part of the
plaque itself.
A) Close the connector;
B) Re-insert the cable;
C) Tighten the screws (1)ti
60
A
(1)
A
A
A
B
B
B
B
05060214 00 09-2021
C
C